A study on the electrical energy requirements in a spinning factory in Vietnam

By: Call Number: AIT Thesis no. ET-94-11 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. ET-94-11Publication details: Bangkok : Asian Institute of Technology, 1994Description: 78 leaves +1 online resourceSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1994 Summary: This study was performed in order to determine the electricity conservation potential in a chosen spinning mill in Vietnam - the Hanoi Combined Spinning and Knitting Enterprise (HANOSIMEX). Attention was focused on the operation of air-conditioning system inside the mill. It was found that a significant saving of electricity can be obtained by using the open air loop operation of air washer within Hanoi weather conditions. The existing operation of airconditioning system at HANOSIMEX seems inefficient and sometimes causes negative saving in electricity consumption, due to the improperly chosen controlling method. A new operation procedure was proposed, which helps to reduce the energy consumption by almost 50%. A computer program was written in FoxPRO to facilitate the calculations. It was used to define the energy consumption and energy saving of different modes of air-conditioning system operation. The results are given in the form of daily, monthly, and annual calculations. The results indicate that OPEN-loop operation can be benefit only if the control indicator is enthalpy of air, but not temperature. Energy savings in the range of 10 to 50% are theoretically possible for air-conditioning system at HANOSIMEX. The evaluation of both technical and economic potential saving of cogeneration application was performed for existing and proposed operation modes of air conditioning system with different scenarios. The results of analysis reveal that cogeneration with double effect absorption chillers can be attractive with the existing subsidized electricity costs, if the scenario of power matching was used. Cogeneration potential can be greatly increased if the electricity cost is at the level of 550 d/kWh (about 5 cent/kWh). In combination with the proposed operation mode of air conditioning system, cogeneration will give extra saving in energy and money, compared with the proposed operation alone.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-94-11 (Browse shelf(Opens below)) 1 Available 30050003107389
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-94-11 (Browse shelf(Opens below)) 2 Available 30050002933397
40-Archives Asian Institute of Technology Library Archives AIT Thesis no. ET-94-11 (Browse shelf(Opens below)) Available 30050120367221

A thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering

Thesis (M.Eng.) - Asian Institute of Technology, 1994

This study was performed in order to determine the electricity conservation potential in a chosen spinning mill in Vietnam - the Hanoi Combined Spinning and Knitting Enterprise (HANOSIMEX). Attention was focused on the operation of air-conditioning system inside the mill. It was found that a significant saving of electricity can be obtained by using the open air loop operation of air washer within Hanoi weather conditions. The existing operation of airconditioning system at HANOSIMEX seems inefficient and sometimes causes negative saving in electricity consumption, due to the improperly chosen controlling method. A new operation procedure was proposed, which helps to reduce the energy consumption by almost 50%. A computer program was written in FoxPRO to facilitate the calculations. It was used to define the energy consumption and energy saving of different modes of air-conditioning system operation. The results are given in the form of daily, monthly, and annual calculations. The results indicate that OPEN-loop operation can be benefit only if the control indicator is enthalpy of air, but not temperature. Energy savings in the range of 10 to 50% are theoretically possible for air-conditioning system at HANOSIMEX. The evaluation of both technical and economic potential saving of cogeneration application was performed for existing and proposed operation modes of air conditioning system with different scenarios. The results of analysis reveal that cogeneration with double effect absorption chillers can be attractive with the existing subsidized electricity costs, if the scenario of power matching was used. Cogeneration potential can be greatly increased if the electricity cost is at the level of 550 d/kWh (about 5 cent/kWh). In combination with the proposed operation mode of air conditioning system, cogeneration will give extra saving in energy and money, compared with the proposed operation alone.

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!