The development of condensing and freezing unit for a solar powered refrigerator

By: Call Number: AIT Thesis no. ET-81-12 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. ET-81-12Publication details: Bangkok : Asian Institute of Technology, 1981Description: viii, 56 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1981 Summary: An ammonia-water intermittent absorption refrigerator with a 0.9 m2 flat plate solar collector and a flooded type evaporator has been constructed. The flat plate collector design has been modified to enhance the ammonia generation as early as possible in the morning. The flat plate solar collector containing 10.5 kgs of aqua-ammonia solution having 50% of ammonia in water is used. The flooded type evaporator is used and a box containing water surrounding the evaporator coil is used to make ice , 2 . 68 kgs of ice being produced obtained after one day's regeneration of ammonia by solar energy. During refrigeration the temperature of the ammonia drops to - 10°c. The overall solar coefficient of performance (cooling effect divided by the solar energy input) is 0.077.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-81-12 (Browse shelf(Opens below)) 1 Available 30050003103313
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-81-12 (Browse shelf(Opens below)) 2 Available 30050003103305
40-Archives Asian Institute of Technology Library Archives AIT Thesis no. ET-81-12 (Browse shelf(Opens below)) Available 30050120352298

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development

Thesis (M.Eng.) - Asian Institute of Technology, 1981

An ammonia-water intermittent absorption refrigerator with a 0.9 m2 flat plate solar collector and a flooded type evaporator has been constructed. The flat plate collector design has been modified to enhance the ammonia generation as early as possible in the morning. The flat plate solar collector containing 10.5 kgs of aqua-ammonia solution having 50% of ammonia in water is used. The flooded type evaporator is used and a box containing water surrounding the evaporator coil is used to make ice , 2 . 68 kgs of ice being produced obtained after one day's regeneration of ammonia by solar energy. During refrigeration the temperature of the ammonia drops to - 10°c. The overall solar coefficient of performance (cooling effect divided by the solar energy input) is 0.077.