Energy flows in AIT water pumping storage and distribution system

By: Call Number: AIT SSPR no. ET-81-2 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Special studies project report ; no. ET-81-2Publication details: Bangkok : Asian Institute of Technology, 1981Description: 85 pSubject(s): Online resources: Dissertation note: Special Studies Project Report (M. Eng.) - Asian Institute of Technology, 1981 Summary: This study include brief discussions of the total water consumption of AIT campus, operation of water pumping system, energy and cost analysis for the present and proposed scheme. Saving of water in the distribution pipe lines has also been discussed. From the study it can be concluded that saving of energy and water in pumping and distribution pipe lines can be done to curtail the consumption of energy of AIT.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT SSPR no. ET-81-2 (Browse shelf(Opens below)) 1 Available 30050003118683
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT SSPR no. ET-81-2 (Browse shelf(Opens below)) 2 Available 30050003118717
22-AIT Thesis (Replacement) Asian Institute of Technology Library Archives AIT SSPR no. ET-81-2 (Browse shelf(Opens below)) 3 Available 30050120567549
40-Archives Asian Institute of Technology Library Archives AIT SSPR no. ET-81-2 (Browse shelf(Opens below)) Available 30050120345516

A special study submitted in partial fulfilment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development

Special Studies Project Report (M. Eng.) - Asian Institute of Technology, 1981

This study include brief discussions of the total water consumption of AIT campus, operation of water pumping system, energy and cost analysis for the present and proposed scheme. Saving of water in the distribution pipe lines has also been discussed. From the study it can be concluded that saving of energy and water in pumping and distribution pipe lines can be done to curtail the consumption of energy of AIT.