Experimental monitoring and computer simulation of a solar air-conditioning system

By: Call Number: AIT Thesis no.ET-85-6 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. ET-85-6Publication details: Bangkok : Asian Institute of Technology, 1985Description: 136 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1985 Summary: The actual performance of a 2 ton YAZAKI WFC600S solar absorption air-conditioning system was monitored by setting up the necessary instrumentation and recording the data on cassette tapes using two Campbell CR21 microloggers . Programs were written to retrieve and process this recorded raw data which was then analyzed in order to study the system performance. Conclusions are drawn and recommendations made in order to ameliorate the system performance . It has been observed that the chiller is very much undersized for the intended load and also that there could be an improvement of system performance by minor variations in control and operational strategy. A detailed simulation program was also developed which models the radiation, collector system, building load a nd the chiller unit while accounting for hysteresis and cycling effects . The simulation assumes a quasi steady state over a 5 minute simulation time step. The simulation program was validated with measured data over a few days. In order to determine the long term performance of the system , the program was run for the entire year and a value of 34.3% f or the annual solar fraction was obtained. Programs were developed in order to simulate the system performance using simplified simulation methods like the o-f Chart, TMD and MIRA methods. These resulted in annual solar fractions of 0. 3500, 0.4163 and 0.3562 respectively which are in accordance wit h the detailed simulations indicating the validity of these procedures to air-conditioning systems and also that a high amount of accuracy is achievable by a judicious choice o f an appropriate s1mplitied design method. This procedure would save a lot of resources on program development and computing time.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.ET-85-6 (Browse shelf(Opens below)) 3 Available 30050120679005
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.ET-85-6 (Browse shelf(Opens below)) Available 30050120353296

A thesis submitted in partial fulfillment of requirements for the degree of Master of Engineering, School of Environment, Resources and Development

Thesis (M.Eng.) - Asian Institute of Technology, 1985

The actual performance of a 2 ton YAZAKI WFC600S solar absorption air-conditioning system was monitored by setting up the necessary instrumentation and recording the data on cassette tapes using two Campbell CR21 microloggers . Programs were written to retrieve and process this recorded raw data which was then analyzed in order to study the system performance. Conclusions are drawn and recommendations made in order to ameliorate the system performance . It has been observed that the chiller is very much undersized for the intended load and also that there could be an improvement of system performance by minor variations in control and operational strategy. A detailed simulation program was also developed which models the radiation, collector system, building load a nd the chiller unit while accounting for hysteresis and cycling effects . The simulation assumes a quasi steady state over a 5 minute simulation time step. The simulation program was validated with measured data over a few days. In order to determine the long term performance of the system , the program was run for the entire year and a value of 34.3% f or the annual solar fraction was obtained. Programs were developed in order to simulate the system performance using simplified simulation methods like the o-f Chart, TMD and MIRA methods. These resulted in annual solar fractions of 0. 3500, 0.4163 and 0.3562 respectively which are in accordance wit h the detailed simulations indicating the validity of these procedures to air-conditioning systems and also that a high amount of accuracy is achievable by a judicious choice o f an appropriate s1mplitied design method. This procedure would save a lot of resources on program development and computing time.

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!