Experimental study on plate shear connector for composite construction

By: Call Number: AIT Thesis no.ST-88-08 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. ST-88-08Publication details: Bangkok : Asian Institute of Technology, 1988Description: 97 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1988 Summary: The capacity and failure mode of plate shaped shear connector with various height and thickness, and mounted on various thickness of bed plate are studied here by u sing the direct pull- out test (see Fig.5 ) and a formula for the calculation of this capacity is proposed in the present thesis . The outcome is compared with the direct push- out test outcome as found by Slutter & Driscoll [ 3 ) and Kiyomiya & Yokota [4) . How the various sizes, shapes and arrangement of s h ear connectors may affect the joint behavior of the composite lapped splice is also presented here from two composite lapped splice beam tests in this study (see Fig.7 ) and some test results from Virach [10) . Some direct pull- out tests with the confinement of stirrups or deformed bars piercing through the shear connector (see Fig.6) are also conducted to clarify their improvement in mechanical behavior of shear connector.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.ST-88-08 (Browse shelf(Opens below)) 3 Available 30050120692511
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.ST-88-08 (Browse shelf(Opens below)) 1 Available 30050160011531

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology

Thesis (M.Eng.) - Asian Institute of Technology, 1988

The capacity and failure mode of plate shaped shear connector with various height and thickness, and mounted on various thickness of bed plate are studied here by u sing the direct pull- out test (see Fig.5 ) and a formula for the calculation of this capacity is proposed in the present thesis . The outcome is compared with the direct push- out test outcome as found by Slutter & Driscoll [ 3 ) and Kiyomiya & Yokota [4) . How the various sizes, shapes and arrangement of s h ear connectors may affect the joint behavior of the composite lapped splice is also presented here from two composite lapped splice beam tests in this study (see Fig.7 ) and some test results from Virach [10) . Some direct pull- out tests with the confinement of stirrups or deformed bars piercing through the shear connector (see Fig.6) are also conducted to clarify their improvement in mechanical behavior of shear connector.