Heave of soil due to pile driving

By: Call Number: AIT Thesis no. 766 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. 766Publication details: Bangkok : Asian Institute of Technology, 1975Description: 76 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1975 Summary: Several types of heave gage were developed and tested to choose the best one for measuring heave of soil due to pile driving in a site where large crossection concrete piles (.425 x .425 x 25.00 m,) were driven. Heave of soil was measured for single piles, groups of two piles and a group of four piles. For single piles, heave was assumed to have a symmetrical shape around the pile. For pile group, contours of equal heave were drawn. Local spots of high heave were observed scattered within the contour. The reason of this phenomina was not known. Volume of heave was estimated to be about 20 - 45 % of total volume of displaced soil. Boundary of soil effected by pile driving was found not changing when driving up to 4 piles,
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. 766 (Browse shelf(Opens below)) 1 Available 3005000303544x
40-Archives Asian Institute of Technology Library Archives AIT Thesis no. 766 (Browse shelf(Opens below)) Available 30050160092457

A thesis submitted in partial fulfilment of the requirements for the degree of Master of Engineering of the Asian Institute of Technology Bangkok Thailand.

Thesis (M.Eng.) - Asian Institute of Technology, 1975

Several types of heave gage were developed and tested to choose the best one for measuring heave of soil due to pile driving in a site where large crossection concrete piles (.425 x .425 x 25.00 m,) were driven. Heave of soil was measured for single piles, groups of two piles and a group of four piles. For single piles, heave was assumed to have a symmetrical shape around the pile. For pile group, contours of equal heave were drawn. Local spots of high heave were observed scattered within the contour. The reason of this phenomina was not known. Volume of heave was estimated to be about 20 - 45 % of total volume of displaced soil. Boundary of soil effected by pile driving was found not changing when driving up to 4 piles,