An assessment of the daylighting potential in (Kaohsiung) Taiwan

By: Call Number: AIT Thesis no. ET-94-6 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. ET-94-6Publication details: Bangkok : Asian Institute of Technology, 1994Description: 226 leaves +1 online resourceSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1994 Summary: This study propose a design procedure for daylighting based on the use of a set of daylight factor curves produced for typical perimeter zones in Electrical Engineering Building (EE) in National Kaohsiung Institute of Technology with its windows. The cases considered include perimeter zones with different window/wall ratio in case study rooms derived from proposed radiation records of three years in Kaohsiung (1991 , 1992, 1993). The procedure is also applied to a case study building. Physical measurement were performed and the results were analyzed and presented. Statisdtical frequency distribution of exterior horizontal illumination were derived using efficacy factor and this values are used for calculation of daylight factor curve and contours. Based on this available illumination, required supplementary artificial lighting were calculated to satisfy a given lighting requirements. The significant use of energy consumption in temperate climate are heat transfer through window and wall into a room. For a typical room, material details of the case study building were used in computer program (in turbo-basic using finite difference method) to compute heat transfer value. Data of typical day (i.e. global and diffuse radiation and temperature) for summer and winter were used in computer program to calculate effective solar radiation. An output data (i.e. effective solar radiation) were used to calculate heat transfer through window. Based on the heat transfer values of window and wall, daylighting vs energy use for typical summer and winter day were calculated.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-94-6 (Browse shelf(Opens below)) 1 Available 30050003107231
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-94-6 (Browse shelf(Opens below)) 2 Available 30050003107249
40-Archives Asian Institute of Technology Library Archives AIT Thesis no. ET-94-6 (Browse shelf(Opens below)) Available 30050120367296

A thesis submitted m partial fulfillment of the requirement for the degree of Master of Engineering

Thesis (M.Eng.) - Asian Institute of Technology, 1994

This study propose a design procedure for daylighting based on the use of a set of daylight factor curves produced for typical perimeter zones in Electrical Engineering Building (EE) in National Kaohsiung Institute of Technology with its windows. The cases considered include perimeter zones with different window/wall ratio in case study rooms derived from proposed radiation records of three years in Kaohsiung (1991 , 1992, 1993). The procedure is also applied to a case study building. Physical measurement were performed and the results were analyzed and presented. Statisdtical frequency distribution of exterior horizontal illumination were derived using efficacy factor and this values are used for calculation of daylight factor curve and contours. Based on this available illumination, required supplementary artificial lighting were calculated to satisfy a given lighting requirements. The significant use of energy consumption in temperate climate are heat transfer through window and wall into a room. For a typical room, material details of the case study building were used in computer program (in turbo-basic using finite difference method) to compute heat transfer value. Data of typical day (i.e. global and diffuse radiation and temperature) for summer and winter were used in computer program to calculate effective solar radiation. An output data (i.e. effective solar radiation) were used to calculate heat transfer through window. Based on the heat transfer values of window and wall, daylighting vs energy use for typical summer and winter day were calculated.

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!