A study of chiller systems (Record no. 114509)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 03038nam a2200385 4500 |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20260818223010.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 280998s1987 th r 0000|0 eng d |
| 035 ## - SYSTEM CONTROL NUMBER | |
| System control number | .b10043184 |
| 099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Classification number | AIT Thesis no.ET-87-5 |
| 100 1# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Patel, Deepa |
| 245 12 - TITLE STATEMENT | |
| Title | A study of chiller systems |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Bangkok : |
| Name of publisher, distributor, etc. | Asian Institute of Technology, |
| Date of publication, distribution, etc. | 1987 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 118 p. |
| 490 1# - SERIES STATEMENT | |
| Series statement | Thesis ; |
| Volume/sequential designation | no. ET-87-5 |
| 500 ## - GENERAL NOTE | |
| General note | A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Eng.) - Asian Institute of Technology, 1987 |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | In this study, steady state models were developed to simulate reciprocating and centrifugal compressor chiller systems, coupled with cooling tower. Additionally models were developed to simulate a chiller system coupled with chilled water storage, operating under different storage modes. The reciprocating chiller model was developed using data from a catalog. The centrifugal chiller model was developed for a chiller in the AIT chiller system. Using actual data from the AIT system, the centrifugal compressor was modelled, and further readings were taken under different conditions to validate the model predictions. Through the actual readings taken, and the models predictions, some improvements in operating practice were suggested. The chilled water storage simulation was done, considering a load curve similar to that of AIT's load on a single chiller. Three different storage operating modes were considered, and these were evaluated using three different electricity rate structures. Replacement of the large chiller by a smaller one, coupled with storage, proved to be the most worthwhile investment, with a payback period of 4 to 5 years for all three electricity rate structures. These results showed it would be feasible for AIT to consider installing chilled water storage. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Refrigeration and refrigerating machinery |
| General subdivision | Research |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Bhattacharya, Sribas C., |
| Relator term | Chairperson |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Exell, Robert H.B., |
| Relator term | Examination Committee |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Prida Wibulswas, |
| Relator term | Examination Committee |
| 710 2# - ADDED ENTRY--CORPORATE NAME | |
| Corporate name or jurisdiction name as entry element | Shell International Petroleum Co. and AFME (French Agency for Energy Management), |
| Relator term | Scholarship Donor |
| 810 2# - SERIES ADDED ENTRY--CORPORATE NAME | |
| Corporate name or jurisdiction name as entry element | Asian Institute of Technology. |
| Title of a work | Thesis ; |
| Volume/sequential designation | no. ET-87-5 |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Materials specified | Full-Text |
| Uniform Resource Identifier | <a href="http://203.159.5.9/ait-thesis/detail.php?q=B19179">http://203.159.5.9/ait-thesis/detail.php?q=B19179</a> |
| 907 ## - LOCAL DATA ELEMENT G, LDG (RLIN) | |
| a | .b10043184 |
| b | mnait |
| c | x |
| 902 ## - LOCAL DATA ELEMENT B, LDB (RLIN) | |
| a | 240409 |
| 998 ## - LOCAL CONTROL INFORMATION (RLIN) | |
| Operator's initials, OID (RLIN) | 2 |
| Cataloger's initials, CIN (RLIN) | 951012 |
| First date, FD (RLIN) | m |
| -- | a |
| -- | x |
| -- | 2 |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnait |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnarc |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | 22-AIT Thesis (Replacement) |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | 40-Archives |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050120678346 |
| CREATED | CREATED : 2014-12-02 |
| RECORD Id | RECORD # : i12762623 |
| LPATRON | LPATRON : 0 |
| LCHKIN | LCHKIN : - |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 0 |
| -- | TOT RENEW : 0 |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050120353023 |
| CREATED | CREATED : 2016-06-15 |
| RECORD Id | RECORD # : i13039076 |
| LPATRON | LPATRON : 0 |
| LCHKIN | LCHKIN : - |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 0 |
| -- | TOT RENEW : 0 |
| Withdrawn status | Lost status | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Cost, normal purchase price | Total checkouts | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | AIT Publications | 18/08/2026 | 50.00 | AIT Thesis no.ET-87-5 | 30050120678346 | 18/08/2026 | 3 | 18/08/2026 | 22-AIT Thesis (Replacement) | ||||
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | Archives | 18/08/2026 | AIT Thesis no.ET-87-5 | 30050120353023 | 18/08/2026 | 18/08/2026 | 40-Archives |

AI Search