Testing of manually operated coiled tube pump (Record no. 119469)

MARC details
000 -LEADER
fixed length control field 02889cas a2200397 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818224318.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110920s1989 th uu|m rtt 0| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b10672709
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no. AE-89-06
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Basunia, Mohammad Ali
245 10 - TITLE STATEMENT
Title Testing of manually operated coiled tube pump
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1989
300 ## - PHYSICAL DESCRIPTION
Extent 122 p.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. AE-89-06
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 1989
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
520 ## - SUMMARY, ETC.
Summary, etc. The performance of a coil tube pump modified in AIT was evaluated both by variable speed motor and by manually. Maximum lift was found to b e 275 cm by using 1 2 turns in the coil. Suitable rpm for manual operation was found to be in between 35 to 25 rpm and within this speed range a labor can operate this pump continuous l y for 45 to 60 minutes. For lift 100-275 cm power requirement for 30 rpm was 16-72 watt and maximum discharge and efficiency were found to be 58 litre/min . and 60 % respectively . For this speed , the optimum angle of operation was found to be 24 degree (7 5 % diameter coil submergence ). Keeping average input power 30 watt (arms/ shoulder) a nd 75 watt (pedaling ) fixed cu t off points at different lifts were calculated. Best cu t - off point for 30 watt and 75 watt occurred at 25 rpm a nd 48 rpm at lift 24 0 cm and 250 cm at which efficiency was 61% and 45 % respectively. The overall performance of the coil tube pump is good. So there is a need to popularize this pump suitable for supplying irrigation water to vegetables, rice and wheat fields in the non-industrialized countries.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Pumping machinery
General subdivision Testing
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Gee-Clough, D.,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Singh, Gajendra,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Gupta, Chandra P.,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Salokhe, Vilas M.,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element The Royal Government of Netherland,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. AE-89-06
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B17818">http://203.159.5.9/ait-thesis/detail.php?q=B17818</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b10672709
b mnait
c s
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240401
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 2
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- s
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120581706
CREATED CREATED : 2014-10-02
RECORD Id RECORD # : i12760213
LPATRON LPATRON : 1028371
LCHKIN LCHKIN : 2018-06-25
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 1
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120364202
CREATED CREATED : 2016-05-27
RECORD Id RECORD # : i12997390
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 50.00   AIT Thesis no. AE-89-06 30050120581706 18/08/2026 3 18/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026     AIT Thesis no. AE-89-06 30050120364202 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!