Calibration and performance evaluation of a vane-in-a-pipe : a water measuring device for partly filled pipes (Record no. 14727)

MARC details
000 -LEADER
fixed length control field 03067cas a2200385 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817172058.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230998s1981 th uu|m rtt 0| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b10126661
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.AE-81-04
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Butlig, Felipe Tancio
245 10 - TITLE STATEMENT
Title Calibration and performance evaluation of a vane-in-a-pipe : a water measuring device for partly filled pipes
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1981
300 ## - PHYSICAL DESCRIPTION
Extent 69 p.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. AE-81-04
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 1981
520 ## - SUMMARY, ETC.
Summary, etc. Three sizes of the vane-in-a-pipe flow measuring device (VIP) were tested at the Hydraulics laboratory of the Asian Institute of Technology. The sizes of VIP tested were 25.4 cm, 30.5 cm, and 38.1 cm, each having a length of 100 cm. These are equivalent to the standard sizes of reinforced concrete pipes (culverts) available in the market. Results of the study showed that the approach and exit flow conditions did not significantly affect the discharge through the device. Likewise, the variations of submergence ratios, did not significantly affect the discharge. Furthermore, discharges calculated using the theoretical equations of the three sizes of VIP did not significantly differ from the discharges calculated using the set of statistically derived discharge equations. All these parameters were tested at the 95% confidence interval as recommended by the International Standards Organization (ISO). Another significant result of the study showed the independence of the moment to variations in velocity for a given discharge. The VIP device is suitable in measuring flow with low velocity and flat gradient channels. It is not suggested as a blanket replacement for other flow measuring devices. Instead, it could serve as a valuable addition to the researchers list of tools complementing the traditional weirs and flumes.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Flow meters
General subdivision Calibration
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Apichart Anukularmphai,
Relator term Chairperson
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Prida Thimakorn,
Relator term Co-Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Olesen, Svend Elsnab,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Government of Australia,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. AE-81-04
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B21507">http://203.159.5.9/ait-thesis/detail.php?q=B21507</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b10126661
b mnait
c x
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 241213
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 2
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- x
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120584767
CREATED CREATED : 2013-10-06
RECORD Id RECORD # : i12731092
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120303515
CREATED CREATED : 2016-05-26
RECORD Id RECORD # : i12993396
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.AE-81-04 30050120584767 17/08/2026 3 17/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026     AIT Thesis no.AE-81-04 30050120303515 17/08/2026   17/08/2026 40-Archives
คัดลอกแล้ว!