Caustic soda recovery in a bottle washing plant using membrane technology (Record no. 15735)

MARC details
000 -LEADER
fixed length control field 03356nam a2200385 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817172336.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field th eng
035 ## - SYSTEM CONTROL NUMBER
System control number .b11558829
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no. EV-96-4
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Hufemia, Anna Marie M.
245 10 - TITLE STATEMENT
Title Caustic soda recovery in a bottle washing plant using membrane technology
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1996
300 ## - PHYSICAL DESCRIPTION
Extent 85 leaves :
Other physical details ill.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. EV-96-4
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M. Eng.) - Asian Institute of Technology, 1996
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering.
520 ## - SUMMARY, ETC.
Summary, etc. The feasibility of recovering caustic soda from bottle washers of a softdrink plant was investigated at pilot-scale using microfiltration (MF) and nanofiltration (NF). This study revealed that the MF/NF system can purify the caustic soda to a certain extent and can be reused back to the bottle washing units. Within the studied pressure ranges, the optimum applied pressure was determined as 101 kPa for MF, and 1,414 kPa for NF with corresponding permeate fluxes of 235 and 15 L/m2-h respectively. Based on these figures, a large-scale installation for the Thai Pure Drinks Ltd., Pathumthani plant was designed and a financial analysis was conducted for the system. The MF/NF system using MEMCOR hollow fiber membranes and MPS-34 (MWC0=300) gave a payback period of seven years and an IRR of 13.7%, rendering the system not financially feasible. An overall water balance was drawn to find alternatives for water purification and reuse in the plant that would lead to reduction of raw water consumption and liquid discharge into the river. It was found that reuse of microfiltered wastewater treatment plant effluent can reduce groundwater input by 40% and liquid discharged to the receiving water by 65.5%. Two proposed options for reclaiming bottle washing rinse water are treatment by reverse osmosis (RO) or purification by ion-exchange (IE). Based on theoretical considerations, an MF/RO system will recover both pure water and concentrated caustic in the process. On the other hand, IE will recover water fit for reuse in the bottle washers. The two conceptual designs have a payback period of3.2 and 3.4 years respectively, while the internal rate of return are 31.3% and 30.5%.
650 10 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Membranes (Technology)
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Visvanathan, C.,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Reutergardh Lars Baetz,
Relator term Examination committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Annachhatre, Ajit P.,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Government of Spain,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. EV-96-4
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B14646">http://203.159.5.9/ait-thesis/detail.php?q=B14646</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b11558829
b mnait
c v
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 241115
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 970102
First date, FD (RLIN) m
-- a
-- v
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30020220000510
CREATED CREATED : 1997-02-01
RECORD Id RECORD # : i11884344
LPATRON LPATRON : 1014388
LCHKIN LCHKIN : 2002-02-08
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 2
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160078977
CREATED CREATED : 2016-05-23
RECORD Id RECORD # : i12985624
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026   AIT Thesis no. EV-96-4 30020220000510 17/08/2026 1 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026   AIT Thesis no. EV-96-4 30050160078977 17/08/2026   17/08/2026 40-Archives
คัดลอกแล้ว!