Climatic design of buildings : (Record no. 18034)

MARC details
000 -LEADER
fixed length control field 04686cam|a2200445 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817172926.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 111198s1984 th r 0000|0 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b10141868
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no. HS-84-06
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Butt, Arif Qayyum
245 10 - TITLE STATEMENT
Title Climatic design of buildings :
Remainder of title a case study of Lahore, Pakistan
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1984
300 ## - PHYSICAL DESCRIPTION
Extent 114 p.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. HS-84-06
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillments oi the requirements for the degree of Master or Science
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Asian Institute of Technology, 1984
520 ## - SUMMARY, ETC.
Summary, etc. The study compares the environmental conditions in terms of comfort in two different cases. One is based on the traditional urban forms for housing and the other more of less a deviation of a borrowed concept sometimes referred to as modern or imitative development. Though the two houses selected are in the same city, they have different planning concepts, which is evident in the two layouts. The two houses selected were put under observation for more then six weeks time. out of which observations of thirty eight days were selected for analysis. During this period Dry bulb Temperature, Wet Bulb Temperature and Air flow were noted at 0630, 1030, 1430 and 1830 hrs. This was done in both the cases for inside and outside, so as to have a clear picture of the behaviour of the houses and the residential envelope, and to establish the difference between the two cases if it exists. In addition to that the effect of induced air flow by mechanical means i.e a ceiling fan, were also studied. In the analysis based on separate parameters, when inside conditions are compared to outside, the traditional house is hotter by 1.4c at 0630, but remains cooler by 2c at 1030 and 2.9c at 1430, respectively. This difference from outside is reduced to 0.9c at 1830. In the case of the modern house, it is hotter by 2.7c at 0630, although remaining cooler by 0.4c at 1030 and 1.1c at 1430. But again it becomes hotter by 1.4c at 1830. in comparing the two houses with each other, the traditional house is found to achieve a lower mean temperature value inside by 1.3-1.7c. For outside, the traditional house has a lower mean value by 0.4c at 0630. This difference almost becomes zero at 1030. But at 1430 and 1830 the traditional house has a higher mean value by 0.4c and 0.9c, respectively. A difference in humidity is established theoretically, but the vapour pressure remains the same. No difference in air flow was found inside the two houses, but outside the traditional house it is more. The analysis based on single parameter shows a difference of 0.4-0.8 CET between the two houses inside. For outside conditions the modern house has a higher mean value by 0.4 CET at 0630. This difference is reduced to 0.3 CET and 0.1 CET at 1030 and 1430, respectively. But at 1830 the traditional house has a higher mean value by 0.3 CET. Thus all the analysis show that the traditional solution has a more comfortable environment, but the difference in the two cases is still a question needing further research, perhaps more of a subjective nature.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Buildings
General subdivision Pakistan
-- Lahore
-- Environmental engineering
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Architecture and climate
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Kammeier, Hans Detlef,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Exell, Robert H.B.,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Onishi, Takashi,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element The Canadian International Development Agency (CIDA),
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. HS-84-06
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B20632">http://203.159.5.9/ait-thesis/detail.php?q=B20632</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b10141868
b mnait
c s
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 251202
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 3
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- s
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003084679
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i10161995
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003084661
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i10162008
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003084687
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i1016201x
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120306070
CREATED CREATED : 2016-05-31
RECORD Id RECORD # : i13006939
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026   AIT Thesis no. HS-84-06 30050003084679 17/08/2026 1 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026   AIT Thesis no. HS-84-06 30050003084661 17/08/2026 2 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026   AIT Thesis no. HS-84-06 30050003084687 17/08/2026 3 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026   AIT Thesis no. HS-84-06 30050120306070 17/08/2026 1 17/08/2026 40-Archives
คัดลอกแล้ว!