Computer aided optimization and design of water treatment systems incorporating particle size distribution (Record no. 20786)

MARC details
000 -LEADER
fixed length control field 07535cas|a2200457 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818084522.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181197s1991 th uzm rtt 00| aseng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b10156318
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Diss. no. EV-91-2
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Dharmappa, Hagare Bhimappa
245 10 - TITLE STATEMENT
Title Computer aided optimization and design of water treatment systems incorporating particle size distribution
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1991
300 ## - PHYSICAL DESCRIPTION
Extent 207 p.
490 1# - SERIES STATEMENT
Series statement Dissertation ;
Volume/sequential designation no. EV-91-2
500 ## - GENERAL NOTE
General note A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor of Engineering, School of Environment, Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Asian Institute of Technology, 1991
520 ## - SUMMARY, ETC.
Summary, etc. Optimization models are required for the optimal design of water and wastewater treatment systems. Although many optimization models have been developed for wastewater treatment systems, very few models are available for water treatment systems. However, these works substantially demonstrate the scope for optimization in identifying the economically and technically feasible alternative designs. The present study is aimed at providing a tool towards this end, which is unique compared to the past works, as it includes: {u2022} Integration of process optimization in system optimization {u2022} Particle size distribution (PSD} for process design and selection {u2022} Membrane processes in the alternative evaluation {u2022} Sludge treatment/handling processes {u2022} Multi-criteria for alternatives evaluation {u2022} Provision for easy incorporation of laboratory/pilot scale data Overall water treatment system design requires determination of: system configuration, level of operation of each process, and individual process design and operating parameters. This can be achieved only through the integration of process optimization in the system optimization, which provides an added advantage of using two separate algorithms. The process optimization, which mostly involves continuous decision variables, can be tactfully handled with some sophisticated optimization tools like nonlinear programming (NLP) or quadratic programming (QP) techniques. On the other hand the system optimization, where the decision has to be made between processes, involves discrete decision variables (and comparatively less number of variables) which can be conveniently handled with simple optimization techniques like enumeration. Recently, many researchers have pointed out the shortcomings of using nonspecific parameters like TU, SS, etc., in the design and selection of processes. They have demonstrated the effect of PSD on the performance of the individual processes, implying that the incorporation of PSD could lead to optimal process design and selection. High and stable water quality, little or no use of disinfectant, compact treatment units, etc . , justify the inclusion of membrane processes in alternatives evaluation. Increasing awareness against environmental pollution and stringent regulations on the handling and disposal of water treatment sludge necessitates the consideration of sludge treatment in the overall system design. Besides cost, other criteria like energy, land, sludge production, etc., often become important in the evaluation of various alternatives. Further, all the optimization techniques rely heavily on the mathematical descriptions of the process/ system which are complicated to formulate. Mathematical models alone cannot fully describe the processes. It is necessary to (iii) supplement the data through laboratory/pilot scale study. Therefore provision should be made for easy incorporation of such data. The principal objective of the present research was to demonstrate the importance of incorporating all the above five features in the overall optimization of water treatment systems consisting of six water (rapid mixing, flocculation, sedimentation, granular filtration, and crossflow microfiltration and ultrafiltration) and thirteen sludge treatment processes. The review of literature revealed the lack of process models and cost functions for certain processes. Thus the objectives also include: {u2022} Development of a new model for crossflow filtration incorporating polydispersity of the influent {u2022} Development of cost functions for crossflow filtration {u2022} Modification of granular filtration cost functions to reflect some of the decision variables The software was developed for system simulation/ optimization, process simulation/optimization, and model parameter estimation. The cost functions developed for crossflow filtration were from the data supplied by a French and Danish company, while the cost data for all other processes were obtained for the USA conditions from the literature . Results of the process optimization demonstrated that the design of a granular filter and flocculator is highly sensitive to particle size distribution in the influent. The cost of a granular filter to treat the influents with the same total quantity of particles but with different influent PSD to the same degree was found to vary between 12-46%. The cost was about 46% higher for the influent with finer particles than with coarser particles. The selection of design and operating parameters was sensitive to influent PSD. In system optimization these cost differences were further amplified yielding 16-64% of difference. The system configurations, level of treatment, and design and operating parameters were different for each influent PSD. Further, for a small water treatment system it was found that the crossflow microfiltration {CFMF) is an economical alternative for some influents, which are difficult to treat with usual treatment system comprising granular filtration. This study is a first step towards more practical oriented optimization modeling of water treatment systems. In this field there is a lot of scope for further research and many potential areas have been discussed.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Water
General subdivision Purification
-- Mathematical models
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Mathematical optimization
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Verink, Johan,
Relator term Chairperson
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Vigneswaran, Saravanamuthu,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Fujiwara, Okitsugu,
Relator term Examination Committee
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Chongrak Polprasert,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Schroder, Hans,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Tebbutt, T.H.Y.,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Japan Government,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Dissertation ;
Volume/sequential designation no. EV-91-2
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B17425">http://203.159.5.9/ait-thesis/detail.php?q=B17425</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b10156318
b mnait
c y
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240411
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 2
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- y
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003058228
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i10184776
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 1
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003058236
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i10184788
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 1
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160005004
CREATED CREATED : 2016-01-02
RECORD Id RECORD # : i12876069
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026   AIT Diss. no. EV-91-2 30050003058228 18/08/2026 1 18/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026   AIT Diss. no. EV-91-2 30050003058236 18/08/2026 2 18/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026   AIT Diss. no. EV-91-2 30050160005004 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!