Design considerations for an underground substation in Pudong area, Shanghai (Record no. 27070)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02961nam a2200385 4500 |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20260818090147.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 011098s1996 th r 0000|0 eng d |
| 035 ## - SYSTEM CONTROL NUMBER | |
| System control number | .b11616441 |
| 099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Classification number | AIT Thesis no.ET-96-18 |
| 100 1# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Hua, Wei |
| 245 10 - TITLE STATEMENT | |
| Title | Design considerations for an underground substation in Pudong area, Shanghai |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Bangkok : |
| Name of publisher, distributor, etc. | Asian Institute of Technology, |
| Date of publication, distribution, etc. | 1996 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 69 leaves + |
| Accompanying material | 1 online resource |
| 490 1# - SERIES STATEMENT | |
| Series statement | Thesis ; |
| Volume/sequential designation | no. ET-96-18 |
| 500 ## - GENERAL NOTE | |
| General note | A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Eng.) - Asian Institute of Technology, 1996 |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | The thesis is Designing Considerations for Underground Substation in Pudong, Shanghai. The main objectives of this study is to analyze the possibility of building the substation and design an underground substation in Pudong. Shanghai, the biggest city in China, the land is limitation for future used. The underground substation has more advantages than normal substations. It is suitable to adopt the underground substation at urban area in Shanghai. In this study, the 220 kV underground substation is designed to meet the data collection. There are three main transformers that will be installed at the underground substation in the future. The capacity of main transformer is 120 MVA. The output voltage is 35 kV, ingoing is 6 and outgoing is 30 for future use. At the first stage, two transformers will be used, ingoing is 4 and outgoing is 20. There are overall designs in this study. The methodology is given below: to choose main transformer, calculate short current, select main electrical equipment, bus arrangement and main transformer protection, layout, and substation electricity etc. The GIS system is the best electrical equipment used in the underground substation. It has a lot of advantages than other electrical equipments. The details are discussed in this study. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Electric substations |
| General subdivision | China |
| -- | Shanghai |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Yu, Cun Yi, |
| Relator term | Chairperson |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Malik, Arif Saeed, |
| Relator term | Examination committee |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Surapong Chiraratananon, |
| Relator term | Examination Committee |
| 710 2# - ADDED ENTRY--CORPORATE NAME | |
| Corporate name or jurisdiction name as entry element | Asian Institute of Technology, |
| Relator term | Scholarship donor |
| 810 2# - SERIES ADDED ENTRY--CORPORATE NAME | |
| Corporate name or jurisdiction name as entry element | Asian Institute of Technology. |
| Title of a work | Thesis ; |
| Volume/sequential designation | no. ET-96-18 |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Materials specified | Full-Text |
| Uniform Resource Identifier | <a href="http://203.159.5.9/ait-thesis/detail.php?q=B14698">http://203.159.5.9/ait-thesis/detail.php?q=B14698</a> |
| 907 ## - LOCAL DATA ELEMENT G, LDG (RLIN) | |
| a | .b11616441 |
| b | mnait |
| c | y |
| 902 ## - LOCAL DATA ELEMENT B, LDB (RLIN) | |
| a | 240401 |
| 998 ## - LOCAL CONTROL INFORMATION (RLIN) | |
| Operator's initials, OID (RLIN) | 0 |
| Cataloger's initials, CIN (RLIN) | 970730 |
| First date, FD (RLIN) | m |
| -- | a |
| -- | y |
| -- | 0 |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnait |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnarc |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | 22-AIT Thesis (Replacement) |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | 40-Archives |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050120742472 |
| CREATED | CREATED : 2014-05-02 |
| RECORD Id | RECORD # : i12758097 |
| LPATRON | LPATRON : 0 |
| LCHKIN | LCHKIN : - |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 0 |
| -- | TOT RENEW : 0 |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050120366512 |
| CREATED | CREATED : 2016-06-14 |
| RECORD Id | RECORD # : i1303540x |
| LPATRON | LPATRON : 0 |
| LCHKIN | LCHKIN : - |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 0 |
| -- | TOT RENEW : 0 |
| Withdrawn status | Lost status | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Cost, normal purchase price | Total checkouts | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | AIT Publications | 18/08/2026 | 50.00 | AIT Thesis no.ET-96-18 | 30050120742472 | 18/08/2026 | 3 | 18/08/2026 | 22-AIT Thesis (Replacement) | ||||
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | Archives | 18/08/2026 | AIT Thesis no.ET-96-18 | 30050120366512 | 18/08/2026 | 18/08/2026 | 40-Archives |

AI Search