Development of a PLC based fuzzy logic process control system using profibus DP ASIC chip (Record no. 28898)

MARC details
000 -LEADER
fixed length control field 03368nas|a2200397 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818090709.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 030309s2007 th uu|m rtt 0| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b1205110x
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ISE-07-36
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Huynh Thanh Vu
245 10 - TITLE STATEMENT
Title Development of a PLC based fuzzy logic process control system using profibus DP ASIC chip
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani, Thailand :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2007
300 ## - PHYSICAL DESCRIPTION
Extent 75 p. :
Other physical details ill.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ISE-07-36
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Mechatronics, School of Engineering Technology
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 2007
520 ## - SUMMARY, ETC.
Summary, etc. The development of the science and technology in communication have been given out new ways and benefits for the automation solutions. Tendency of networking, decentralization, softening, and standardization are four basics among many characteristics of this changing. For the controlling problem, the methodology and quality of the control system are the first priorities that the integrated system engineer has to decide. It will be the conventional control method or the new one is a question should be considered. Nowaday, constructing an automation system is not the problem of choosing or not, it is the problem of what kind of the network and controlling method should be chosen. In this thesis, the research will focus mainly on the development of the Profibus DP for smart device and the development of the PLC based Fuzzy controller in the process control. The development board 1m I 83 and 1m I 84 will be combined with the microprocessor system to make the interface to the user devices. With the open architecture, these two-interface modules allowed the user easy to integrated the normal devices to the Profibus system. The fuzzy logic controllers for the Temperature, Pressure control, and flow and level control will be developed by the Structure Control Language (SCL), a programming language for the programmable logic controller. In order to monitor the behavior of the controllers and process, the simulation for the steam boiler process will be built. The WinCC will handle the function of HMI and archiving variables in the process
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Fuzzy logic
General subdivision Automatic control
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Application-specific integrated circuits
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Afzulpurkar, Nitin V.,
Relator term Chairperson
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Manukid Parnichkun,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Parekh, Moiz,
Relator term Examination committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology Fellowship,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ISE-07-36
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="hhttp://203.159.5.9/ait-thesis/detail.php?q=B11024">hhttp://203.159.5.9/ait-thesis/detail.php?q=B11024</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b1205110x
b mnait
c u
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240328
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 090303
First date, FD (RLIN) m
-- a
-- u
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120804652
CREATED CREATED : 2014-03-20
RECORD Id RECORD # : i12776130
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160031190
CREATED CREATED : 2016-03-03
RECORD Id RECORD # : i12889829
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 50.00   AIT Thesis no.ISE-07-36 30050120804652 18/08/2026 3 18/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026     AIT Thesis no.ISE-07-36 30050160031190 18/08/2026 1 18/08/2026 40-Archives
คัดลอกแล้ว!