Development of OTTV base energy estimation model for energy management in building (Record no. 29428)

MARC details
000 -LEADER
fixed length control field 03280nas|a2200397 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818090902.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 040615s2003 th uzm rtt 00| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b11929054
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ET-03-11
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Vichuda Mettanant
245 10 - TITLE STATEMENT
Title Development of OTTV base energy estimation model for energy management in building
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani, Thailand :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2003
300 ## - PHYSICAL DESCRIPTION
Extent 82 leaves
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-03-11
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering.
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 2003
520 ## - SUMMARY, ETC.
Summary, etc. Nowadays, Energy conservation of commercial building is well-known but there are some problems in evaluate energy saving from improving measure suggested by energy consultants. Before giving advice to these building owners who will make decision to invest money to the energy conservation project, we need to have some method, which accurate in measuring the energy consumption of building. OTTV formulation is done first because it is a heat gain through building envelops transferring to load of air-conditioning system, which is the largest part of energy use in commercial building. The regression method is used for evaluating constant values of the equation which are equivalent temperature difference of opaque wall, average temperature difference between indoor and outdoor and Solar Factor. Then, Energy equation is evaluated by regressing coefficients of internal loads generating to air-conditioning system so cooling load of air-condition system can be calculated. After that, summation of energy use by air-condition system with energy use by lighting system, equipments and other systems is formulated to energy equation. The DOE2 simulation program is used to calculate cooling load of generic building at different parameters. The generic building is an office building, which is the most common type of commercial buildings. The results from DOE2 program will be compared with another simulation program, which is EP Program. Energy equation is used to calculate energy use of existing building and compared results with audit report data.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Buildings
General subdivision Power supply
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Buildings
General subdivision Energy consumption
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Surapong Chirarattananon
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Kumar, Sivanappan
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Bhattacharya, Sribas C.
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Royal Thai Government
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-03-11
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href=" http://203.159.5.9/ait-thesis/detail.php?q=B11540"> http://203.159.5.9/ait-thesis/detail.php?q=B11540</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b11929054
b mnait
c u
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240417
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 040611
First date, FD (RLIN) m
-- a
-- u
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120601074
CREATED CREATED : 2013-11-21
RECORD Id RECORD # : i12747750
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160046883
CREATED CREATED : 2016-07-06
RECORD Id RECORD # : i13020122
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 50.00   AIT Thesis no.ET-03-11 30050120601074 18/08/2026 3 18/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026     AIT Thesis no.ET-03-11 30050160046883 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!