Effects of harmonics and voltage flickers on a power system in Samutprakarn province, Thailand (Record no. 35157)

MARC details
000 -LEADER
fixed length control field 03121nas a2200385 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818095244.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 280200s1999 th uu m rtt 0| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b1177759x
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ET-99-29
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Damrong Kamolpattananan
245 10 - TITLE STATEMENT
Title Effects of harmonics and voltage flickers on a power system in Samutprakarn province, Thailand
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1999
300 ## - PHYSICAL DESCRIPTION
Extent 75 leaves
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-99-29
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering. School of Environment Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 1999
520 ## - SUMMARY, ETC.
Summary, etc. In recent years, power quality becomes more critical because of the increase in the number of loads sensitive to power disturbances, and as the loads themselves have become major causes of the degradation of power quality. Therefore, power quality responsibility lies with three main groups: the utility company, the customer group, and the manufacturing group. A number of load types used in industries cause harmonic current and voltage fluctuation such as electric arc furnaces (EAFs) that are found in Steel Manufacturing Facility. Due to the arc furnace load, the significant voltage distortion will occur in power system, which effects the other customer in the same area. In the utility side, the system configuration also causes voltage distortion too. Simulation results from HI_ WA VE program show that the fifth harmonic resonance occurs in power system and by changing the configuration of capacitor bank at distribution feeders can solve this problem. Electric arc furnaces cause voltage fluctuation on account of the oscillated of reactive power. The field measurements illustrate the effect of this voltage fluctuation on another customers in the same distribution area. Consequencely, by adding the static VAR compensator at the steel manufacturing can reduced the flicker problem, which can be seen by the simulation results of EMTDC program.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric power transmission
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Surapong Chiraratananon,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Yu, Cun Yi,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Dhadbanjan, Thukaram,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Electricity Generating Authority of Thailand,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-99-29
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B12792">http://203.159.5.9/ait-thesis/detail.php?q=B12792</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b1177759x
b mnait
c u
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240421
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 000228
First date, FD (RLIN) m
-- a
-- u
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120731871
CREATED CREATED : 2014-03-02
RECORD Id RECORD # : i12754663
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120365399
CREATED CREATED : 2016-06-15
RECORD Id RECORD # : i1303733x
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 50.00   AIT Thesis no.ET-99-29 30050120731871 18/08/2026 3 18/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026     AIT Thesis no.ET-99-29 30050120365399 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!