Energy analysis of cogeneration in a sugar mill (Record no. 37081)

MARC details
000 -LEADER
fixed length control field 03174nas|a2200397 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818095741.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 261198s1986 th uzm rtt 00| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b1023973x
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT RSPR no. ET-86-10
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Balakrishnan, Sadras Vasudev
245 10 - TITLE STATEMENT
Title Energy analysis of cogeneration in a sugar mill
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1986
300 ## - PHYSICAL DESCRIPTION
Extent 93 p.
490 1# - SERIES STATEMENT
Series statement Research studies project report ;
Volume/sequential designation no. ET-86-10
500 ## - GENERAL NOTE
General note A research study (6 credits) submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1986
520 ## - SUMMARY, ETC.
Summary, etc. The cogeneration system in Khon - kaen sugar mill ltd., located in Khon - kaen province was studied and the energy and exergy analysis of the components of the cogeneration system was carried out . The cogeneration system consists of four boilers each of 80t /hr capacity , three 5Mw turbogenerators and five 1 5 00HP milling turbines and one 2000HP unigator turbine. The best case efficiency of the boiler was found to be 62. 74 % and the worst case efficiency was found to be 60 . 25%. Using the component analysis the analysis of the cogeneration system as a whole was carried out. The energy analysis indicate that the maximum first law efficiency of the cogeneration system recorded was 60. 3 9% The cogeneration system was modeled base don the experimental data collected and a computer program was written which takes into account the capacity limitations of the components of the system. Based on the first and second law analysis and on the model developed energy conservation measures were suggested to improve the efficiency of the cogeneration system. Major energy conservation measures suggested were, reduction of excess air supplied to the boilers, installation of bagasse drier (The source o f drying of bagasse will be the flue gas) and operating the turbo generators, milling turbines and unigator turbines at their rated capacity .
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Energy conservation
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cogeneration of electric power and heat
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Prida Wibulswas,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Bhattacharya, Sribas C.,
Relator term Co-Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Sauter-Servaes, Florian,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element CEC,
Relator term Scholaship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Research studies project report ;
Volume/sequential designation no. ET-86-10
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B19506">http://203.159.5.9/ait-thesis/detail.php?q=B19506</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b1023973x
b mnait
c y
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240401
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 2
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- y
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120615025
CREATED CREATED : 2012-11-09
RECORD Id RECORD # : i12694782
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160016290
CREATED CREATED : 2016-03-31
RECORD Id RECORD # : i12916742
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026   AIT RSPR no. ET-86-10 30050120615025 18/08/2026 3 18/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026   AIT RSPR no. ET-86-10 30050160016290 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!