Experimental evaluation of retrofitting of partially damaged masonry houses using fiber reinforced coating (Record no. 42050)

MARC details
000 -LEADER
fixed length control field 02968nas a2200385 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818113037.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 260130s20249999th u ms t 000 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b12473625
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ST-24-07
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Kafle, Nitisha
245 10 - TITLE STATEMENT
Title Experimental evaluation of retrofitting of partially damaged masonry houses using fiber reinforced coating
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani, Thailand :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2024
300 ## - PHYSICAL DESCRIPTION
Extent 103 leaves :
Other physical details ill.+
Accompanying material 1 online resource
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ST-24-07
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Structural Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M. Eng.) - Asian Institute of Technology, 2024
520 ## - SUMMARY, ETC.
Summary, etc. This study proposes a potential solution to partially damaged unreinforced masonry buildings by fiber-reinforced paint. Static and dynamic tests were conducted, using a UTM machine and shake table, respectively, to assess the efficacy of the retrofitting technique. Results showed significant improvement in seismic capacity for retrofitted masonry, with enhanced performance in both in-plane and out-of-plane tests compared to unreinforced counterparts. Shake table tests on building models demonstrated the retrofitted structure's ability to withstand large deformations and dissipate energy effectively. Furthermore, ductility of the retrofitted structures was found to increase, indicating their ability to sustain large deformations without loss of structural integrity. Minimal dust emission during shaking table tests emphasized the safety aspect of the retrofitting method. Overall, the experiment concluded that fiber-reinforced paint is highly effective for enhancing the seismic resilience of partially damaged brick masonry. In this study, fiber-reinforced paint was the only retrofitting method considered for retrofitting.Thus, future investigations could involve combining localized failure repairs with fiber-reinforced paint to enhance its performance.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Fiber-reinforced concrete
General subdivision Evaluation
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Buildings
General subdivision Retrofitting
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Earthquake resistant design
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Krishna, Chaitanya,
Relator term Chairperson
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Thanakorn Pheeraphan,
Relator term Examination Committee
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Raktipong Sahamitmongkol,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Computer and Structures Inc.(CSI), USA,
Relator term Scholarship Donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element AIT Scholarships,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ST-24-07
856 40 - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/Viewer/viewer.php?id=B23524">http://203.159.5.9/ait-thesis/Viewer/viewer.php?id=B23524</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b12473625
b mnarc
c a
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 260216
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 260211
First date, FD (RLIN) m
-- h
-- a
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 67-Electronic Resource
909 ## - LOCAL ITEMS USED
Barcode Barcode : -
CREATED CREATED : 2026-01-30
RECORD Id RECORD # : i13570286
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026   AIT Thesis no.ST-24-07 18/08/2026 1 18/08/2026 67-Electronic Resource
คัดลอกแล้ว!