Feasibility study for a separate air-conditioning system at AIT center (Record no. 43625)

MARC details
000 -LEADER
fixed length control field 03458nas|a2200385 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818113534.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 261198s1985 th uzm rtt 00| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b1027392x
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT RSPR no. ET-85-5
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Panu Chandhaprayoon
245 10 - TITLE STATEMENT
Title Feasibility study for a separate air-conditioning system at AIT center
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1985
300 ## - PHYSICAL DESCRIPTION
Extent 97 p.
490 1# - SERIES STATEMENT
Series statement Research studies project report ;
Volume/sequential designation no. ET-85-5
500 ## - GENERAL NOTE
General note A research study summitted in partial fulfilment of the requirements for the Degree of Master of Engineering, School of Environment, Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1985
520 ## - SUMMARY, ETC.
Summary, etc. AIT Center is the only building in the campus to which the existing central chiller plant has to supply the chilled water for maintaining physical comfort in the building during the night. The cooling load profile of the building resulted from cooling load estimation shows the oversize capacity of the existing 340-ton chiller unit especially during the night. The maximum of cooling load of the building is estimated to be about 230 tons (807 KW) occurring at bout 1500 hr in April. By considering the cooling load profile, the feasible period for an energy conservation measure appears to occur between 1900-0700 hrs. The thermodynamic analysis, by both first law and second law, consistently indicates that poor efficiencies of the existing chiller operation occur during the night. The average coefficient of performance, COP and the average exegetic efficiency of the whole system are just about 2.19 and 15.5% respectively. After the simulation of a proposed separate small chiller set of two 90-ton units, both thermodynamic and various economic analyses indicate the feasibility of the recommended system operating between 1900-0700 hr. the COP and the exegetic efficiency of the proposed system would be 3.55 and 24.7% respectively. the proposed system will save the electricity bill by about 645,000 Baht per years. for AIT and the investment cost can be recovered within 4 years. The refrigeration cost of the proposed system would be 1.13 Baht per KHh of refrigeration lower than that of the existing system. The net present worth, benefit cost ratio, and internal rate of return of the proposed system also show the positive results which are about 874,000 Baht, 1.29, and 20% respectively.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Air conditioning
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Prida Wibulswas,
Relator term Chairpeson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Exell, Robert H.B.,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Reddy, T. A.,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element DAAD,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Research studies project report ;
Volume/sequential designation no. ET-85-5
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B19831">http://203.159.5.9/ait-thesis/detail.php?q=B19831</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b1027392x
b mnait
c y
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240401
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 2
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- y
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120615157
CREATED CREATED : 2012-11-09
RECORD Id RECORD # : i12694630
LPATRON LPATRON : 1029161
LCHKIN LCHKIN : 2019-11-19
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 1
-- TOT CHKOUT : 2
-- TOT RENEW : 5
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160016456
CREATED CREATED : 2016-03-31
RECORD Id RECORD # : i12916584
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026   AIT RSPR no. ET-85-5 30050120615157 18/08/2026 3 18/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026   AIT RSPR no. ET-85-5 30050160016456 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!