A feasibility study on ice storage in an office building in Bangkok (Record no. 43699)

MARC details
000 -LEADER
fixed length control field 03411nam a2200433 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818113549.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 280998s1990 th r 0000|0 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b10029151
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no. ET-90-1
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name San Chatkaewvorakul
245 12 - TITLE STATEMENT
Title A feasibility study on ice storage in an office building in Bangkok
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1990
300 ## - PHYSICAL DESCRIPTION
Extent 159 p.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-90-1
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 1990
520 ## - SUMMARY, ETC.
Summary, etc. A feasibility study on ice storage in an office building in Bangkok, which has 24 floors in one block and 2 floors in another block, is described in this thesis. The ice storage under a partial and modified demand-limited design with constant proportion control are considered. It has been found from a preliminary results of an energy audit that the air conditioning system consumed about 61.1% of total building electrical energy consumption and chillers consumed about 51.8% of total electrical energy consumption in air-conditioning (A/C) system. The average coefficient of performance of the chillers is 4.77 at the daytime (450 ton chiller) and 3.45 at the nighttime (50 ton chiller) . The average system efficiency is 1.55 kW/ton. The DOE- 2. lC building energy analysis computer program was used to analyze the energy consumption in the studied building. Conventional heating ventilation air-conditioning (HVAC) system was compared to ice storage systems using simple payback periods, net present value and internal rate of return. It was found that at present electricity rate structure , partial storage is more economically feasible than other operating modes . But under a number of alternative time-of-day (TOD) rate structure, the modified demand-limited storage system present a better economic feasibility, especially when the energy charge for the off-peak period is differentiated from other period.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heat storage
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cooling load
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Surapong Chiraratananon,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Bhattacharya, Sribas C.,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Mohanty, B.,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Lapillonne, Bruno,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element The Government of France,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-90-1
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B18305">http://203.159.5.9/ait-thesis/detail.php?q=B18305</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b10029151
b mnait
c x
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240409
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 2
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- x
-- 2
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003105292
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i10012096
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003105284
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i10012102
LPATRON LPATRON : 1015538
LCHKIN LCHKIN : 2003-02-08
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 3
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120344782
CREATED CREATED : 2016-06-15
RECORD Id RECORD # : i13039738
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 10.00   AIT Thesis no. ET-90-1 30050003105292 18/08/2026 1 18/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 10.00   AIT Thesis no. ET-90-1 30050003105284 18/08/2026 2 18/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026     AIT Thesis no. ET-90-1 30050120344782 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!