Flicker problem assessment of different wind turbine models in a distribution system (Record no. 45518)

MARC details
000 -LEADER
fixed length control field 03221nas a2200421 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818114028.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170831s2014 th uu m rtt 0 a eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b1219007x
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ET-14-12
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Krongsiri Mongkholkaset
245 10 - TITLE STATEMENT
Title Flicker problem assessment of different wind turbine models in a distribution system
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani, Thailand :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 41 leaves :
Other physical details ill. +
Accompanying material 1 online resource
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-14-12
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Energy
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 2014
520 ## - SUMMARY, ETC.
Summary, etc. In the distribution systems, the wind turbine installation may cause problems on power quality during continuous operations. The main power quality problems are voltage fluctuation, flicker and harmonics. Power fluctuations due to the change of wind speed and grid conditions may cause flicker emission. Moreover, the main problem of the fixed speed wind turbine is flicker. Therefore, the assessment of power quality in such systems, especially in term of flicker emission, is a very important issue. This thesis presents the effects of wind turbine installation on flicker emission during continuous operation, namely wind characteristics and grid conditions. The effects of penetration levels and types of wind turbine are investigated in this study. A flickermeter based on IEC 61000 - 4 - 15 is used to evaluate the flicker severity. Installing a series capacitor can help mitigating the emission of voltage flicker. The distribution system used in this study is limited to one practical test system in Samoeng District, Thailand. The simulation and modeling have been implemented by using DIgSILENT PowerFactory software.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Wind turbines
General subdivision Evaluation
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Wind turbines
General subdivision Control
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Singh, Jai Govind,
Relator term Chairperson
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Weerakorn Ongsakul,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Dhakal, Shobhakar,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element PEA,
Relator term Scholarship donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology Education Cooperation Project,
Relator term Scholarship donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology Fellowship,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-14-12
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B02308">http://203.159.5.9/ait-thesis/detail.php?q=B02308</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b1219007x
b mnait
c m
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240418
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 170831
First date, FD (RLIN) m
-- a
-- m
-- 0
962 ## -
-- 000:001:PDF:b1219007:003345:0:0:0:0:0:0
-- Click to view Abstract
-- n
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120518807
CREATED CREATED : 2017-08-31
RECORD Id RECORD # : i13094920
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120518815
CREATED CREATED : 2017-08-31
RECORD Id RECORD # : i13094932
LPATRON LPATRON : 1029062
LCHKIN LCHKIN : 2019-01-25
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 1
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 50.00   AIT Thesis no.ET-14-12 30050120518807 18/08/2026 1 18/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 50.00   AIT Thesis no.ET-14-12 30050120518815 18/08/2026 2 18/08/2026 20-AIT Publication
คัดลอกแล้ว!