The analysis of lightning risk for a 500KV GIS substation : (Record no. 4849)

MARC details
000 -LEADER
fixed length control field 03194nas|a2200397 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817162400.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220200s1999 th uu m rtt 00| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b11778386
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ET-99-17
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Pham Quang Huy
245 14 - TITLE STATEMENT
Title The analysis of lightning risk for a 500KV GIS substation :
Remainder of title a case study in Vietnam
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1999
300 ## - PHYSICAL DESCRIPTION
Extent 86 leaves
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-99-17
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering. School of Environment Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 1999
520 ## - SUMMARY, ETC.
Summary, etc. The major problem of insulation level of GIS substation is the overvoltages due to lightning, especially with high value of lightning current. This study concerned with electromagnetic transients to evaluate the failure risk of insulation of equipment. It is more importance because this study is applied for 500kV GIS substation, the new equipment with many advantages of small space requirement, low maintenance cost, low environmental impact, etc. In this study, modeling of the power system and lightning source has been done in the transient state. By using EMTP program, the overvoltages due to lightning have been calculated in various cases of changing lightning current, point of lightning impact, phase angle of power frequency voltage, i.e .. The overvoltage results inside the 500kV GIS are collected for evaluating the risk of failure. A method for estimating the risk of failure of an apparatus as a result of lightning strikes on the transmission lines has been developed to meet the requirements of quick and low-variability calculation. The results shown that with tower footing resistance is 10 ohms· or less, the risk due to lightning can be accepted. Otherwise, the solution to reduce the risk of failure for 500kV GIS substation could be carried out by installing surge anester, reducing tower surge impedance, re-arrange the spans, etc. The calculation can be used efficiently as a calculated process of substation design.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric substations
Geographic subdivision Vietnam
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Lightning protection
Geographic subdivision Vietnam
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Surapong Chiraratananon,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Yu, Cun Yi,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Dhadbanjan, Thukaram,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Sida,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-99-17
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B12781">http://203.159.5.9/ait-thesis/detail.php?q=B12781</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b11778386
b mnait
c u
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240421
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 000222
First date, FD (RLIN) m
-- a
-- u
-- 4
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120731996
CREATED CREATED : 2014-03-02
RECORD Id RECORD # : i12754730
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120365480
CREATED CREATED : 2016-06-15
RECORD Id RECORD # : i13037067
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.ET-99-17 30050120731996 17/08/2026 3 17/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026     AIT Thesis no.ET-99-17 30050120365480 17/08/2026   17/08/2026 40-Archives
คัดลอกแล้ว!