Analytical study of factors affecting to electromechanical oscillations in power systems (Record no. 5372)

MARC details
000 -LEADER
fixed length control field 04946nas|a2200397 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817162537.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 070824s2006 th uu|m rtt 0| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b12020424
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ET-06-19
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Angammana, Mohottige Chitral Jayasanka
245 10 - TITLE STATEMENT
Title Analytical study of factors affecting to electromechanical oscillations in power systems
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani, Thailand :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2006
300 ## - PHYSICAL DESCRIPTION
Extent 130 p. :
Other physical details ill.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-06-19
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 2006
520 ## - SUMMARY, ETC.
Summary, etc. The origin of inter-area oscillations can be illustrated by a spring-mass system, which is a mechanical analogue of a two area power system. The masses represent the aggregated inertias of the rotating generators and turbines of both areas, each having a well meshed grid inside the areas. The spring corresponds to a relatively weak interconnection line. Electromechanical oscillations are inherent to interconnected power systems. However, the frequency of oscillations and the number of generators that oscillate in any electromechanical oscillatory node depend on the structure of the power system network. Low frequency electromechanical oscillations occur when existing generation and load areas are connected to other similar areas by relatively weak transmission lines. Weak interconnections are obvious in many interconnected systems, for example, when two independent electric grids arc interconnected for the first time through one or two tie lines. However, in systems that have been interconnected for some time, such as the WSCC interconnected system, and that are being stressed by increased load, weak links are less obvious. Often, the first signs of trouble are low frequency oscillations becoming unstable. The connection between loading and stability is not always understandable. It is also unclear which contingencies may lead to oscillatory instability. Electromechanical oscillations in power systems are essentially linear in character. That is, the frequency and damping of an oscillation may be calculated from a dynamic system model linearized for small changes about a particular operating condition. The eigenvalues of the linear model give the frequency and damping of the system oscillations. The eigenvectors indicate the relative magnitude and phase angle between the state variables (in classical generator models, there are two states per generator, the changes in rotor angle and speed). In systems having a number of low frequency inter-area modes, we can use the coherency of the angle components of eigenvectors of the inter-area modes to identify relatively closely coupled generators. More than this, we can also identify those buses that have voltage phase angles that are coherent with the angles of a set of coherent generators. This divides the system into sets of coherent buses and generators equal in number to the number of inter-area modes. The tie lines between one coherent group and another are the weak connections that are the root cause of the inter-area oscillations. Here we list documented cases of oscillatory instability and review to illustrate the characteristics of the problems faced if oscillatory stability is not well managed. The cases arc described briefly in chapter 3. This Thesis examines in detail the relationship between low frequency oscillations and network parameters such as line reactance as well as loading. The basis of the analytical study will be on single machine infinite bus system. The results will be proved by eigenvalue analysis and time domain simulation. Further clarification has been done using two area test system
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Oscillations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric power systems
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Nadarajah, Mithulananthan,
Relator term Chairperson
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Surapong Chiraratananon,
Relator term Examination Committee
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Weerakorn Ongsakul,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Development Bank - Japan Scholarship Program (ADB - JSP),
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-06-19
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B10585">http://203.159.5.9/ait-thesis/detail.php?q=B10585</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b12020424
b mnait
c u
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240401
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 070824
First date, FD (RLIN) m
-- a
-- u
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120602080
CREATED CREATED : 2014-11-02
RECORD Id RECORD # : i12761709
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 1
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120369391
CREATED CREATED : 2016-07-06
RECORD Id RECORD # : i13021059
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.ET-06-19 30050120602080 17/08/2026 3 17/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026     AIT Thesis no.ET-06-19 30050120369391 17/08/2026   17/08/2026 40-Archives
คัดลอกแล้ว!