Application of Wattmon for system design and performance improvement of solar PV systems (Record no. 6942)

MARC details
000 -LEADER
fixed length control field 05050nas a2200433 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817163006.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170901s2014 th uu m rtt 0 a eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b1219024x
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ET-14-27
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Thanongsak Kaewsaibuathong
245 10 - TITLE STATEMENT
Title Application of Wattmon for system design and performance improvement of solar PV systems
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani, Thailand :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 90 leaves :
Other physical details ill. +
Accompanying material 1 online resource
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-14-27
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Energy
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 2014
520 ## - SUMMARY, ETC.
Summary, etc. This research examined the battery charging and discharging characteristic by grid and by solar PV system to understand the conditions for improving the performance of the battery by the user. A study was also conducted to show how an effective load management in solar home system powered by PV using a monitoring and control device (Wattmon) can help in improving the overall performance of the system. The improvements would be in terms of increased useful energy output, increased overall efficiency, etc. Experiments were conducted to study the patterns of battery charging by solar and grid electricity. It was found that the charge efficiency by solar electricity is limited by the PV module efficiency, while the charging efficiency by grid electricity was around 80 %, though only 65 % of charging was observed during the bulk charge state and the remaining charging takes a long time. Therefore, the option to improve charging efficiency in case of a PV system is by using the backup source only during the bulk charge state. Experimental studies on the patterns of battery discharging were conducted at c-rate of C/10, C/14, C/20 and C/30, respectively. It was found that discharge efficiency increases when discharge current is low. This needs effective load management to improve the performance. In addition, the discharge time of battery can be calculated from different state of charge (SOC) conditions and discharge rate by Peukert{u2019}s equation and rate of SOC{u2019}s equation. This information can help to plan using the energy efficiently. The demonstration of how a Solar Home System (SHS) will continually supply essential load by load management according to SOC was also done. Essential load could be supplied when SOC ranges from 100 % to 30 %, and the non-essential loads could be supplied when SOC ranges from 100 % to 65 %. This way of energy supply to the load by the battery will improve the performance by lower discharge current rate. This load management by knowing the state of charge and the types and needs of the load using the Wattmon monitoring and control device was shown to be effective. However, a backup source is needed in stand-alone solar PV system in order to guaranty the reliability of the system during continued rainy or bad weather conditions. Another demonstration was carried out using excess energy to supply buffer load (the excess energy was produced by the PV system after having charged the battery fully). This will help improve the performance of solar PV system by using direct electricity from PV output to power the buffer load, and thus which can avoid losses, and increasing the useful energy supplied by the PV module. In summary, this research demonstrates how the overall efficiency and reliability of stand-alone solar PV system can be improved by using a monitoring and control device called 2Wattmon3.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Storage batteries
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Solar cells
General subdivision Design and construction
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Photovoltaic power systems
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Kumar, Sivanappan,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Singh, Jai Govind,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Mohanty, Brahmanand,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element PEA,
Relator term Scholarship donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology Education Cooperation Project,
Relator term Scholarship donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology Fellowship,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-14-27
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B02323">http://203.159.5.9/ait-thesis/detail.php?q=B02323</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b1219024x
b mnait
c m
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240418
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 170901
First date, FD (RLIN) m
-- a
-- m
-- 0
962 ## -
-- 000:001:PDF:b1219024:003359:0:0:0:0:0:0
-- Click to view Abstract
-- n
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120518559
CREATED CREATED : 2017-01-09
RECORD Id RECORD # : i13095225
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120518526
CREATED CREATED : 2017-01-09
RECORD Id RECORD # : i13095237
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 6
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.ET-14-27 30050120518559 17/08/2026 1 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.ET-14-27 30050120518526 17/08/2026 2 17/08/2026 20-AIT Publication
คัดลอกแล้ว!