Modeling of building thermal response (Record no. 77583)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 04876nam a2200433 4500 |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20260818155525.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 290998s1994 th r 0000|0 eng d |
| 035 ## - SYSTEM CONTROL NUMBER | |
| System control number | .b11407712 |
| 099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Classification number | AIT Thesis no. ET-94-4 |
| 100 1# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Diopenes, Roberts G. |
| 245 10 - TITLE STATEMENT | |
| Title | Modeling of building thermal response |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Bangkok : |
| Name of publisher, distributor, etc. | Asian Institute of Technology, |
| Date of publication, distribution, etc. | 1994 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 90 leaves +1 online resource |
| 490 1# - SERIES STATEMENT | |
| Series statement | Thesis ; |
| Volume/sequential designation | no. ET-94-4 |
| 500 ## - GENERAL NOTE | |
| General note | A thesis submitted m partial fulfillment of the requirements for the degree of Master of Engineering |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Eng.) - Asian Institute of Technology, 1994 |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Knowledge and understanding of the thermal interactions in an air-conditioned building have become a necessity in the aspect of providing comfort as well as for rational use of energy. The heat transfer occurring in a building is a dynamic phenomenon influenced by many factors. Heat gain through the building envelope is highly variable with time due to the fluctuations of solar radiation intensity, ambient temperature and other environmental conditions. This heat gain is controlled by the thermal properties of the building envelope material. Similarly, other heat sources within the building contribute to the dynamic behavior of heat transmission and removal. The thermal characteristic of the building envelope and content serves as a modulator of the rate of heat transfer into the space and the heat removal as well. The building interior structure and furnishings have finite thermal cairacitance and therefore have the ability to store heat. The instantaneous heat input into the space for instance may not most of the time be equal to the rate of heat removal by the air conditioning equipment. Some of this heat is absorbed and stored by the building interior elements. After some time this heat is released and becomes a cooling load of the space. The effect is a time delay of the maximum rate of heat transfer at the same time reduction in the magnitude of the peak load. This phenomenon is highly prevalent in structures of heavy construction than in lightly constructed ones. In this study, an attempt is made to develop a model to represent this dynamic behavior in a building. Simple electrical analog networks were used to characterize the thermal network. Submodels were developed for each heat load factors and elements. These submodels were integrated forming a thermal system describing the dynamic thermal interactions. Data collected from an office building in Metro Manila, Philippines were used to simulate the model using a finite difference procedure. The simulation results show that the instantaneous heat gain into the building is highly responsive to the variation in solar and ambient conditions. Peak heat gain is experienced in the early afternoon hours where solar radiation and ambient temperature are at there maximum. This is due to the fact that the building facades are covered mostly with glass. The results also show that the building interior mass significantly affects the cooling load of the space. Almost half of the total cooling load during the day time where there is air conditioning comes from the heat stored in the interior building mass. The model developed was applied to determine the cooling load of the building under a selected design condition. Results indicate a substantial difference in the magnitude and time of the peak cooling load. |
| 650 10 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Heat |
| General subdivision | Transmission |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | S. Chirarattananon, |
| Relator term | Chairperson |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Karmazsin, E., |
| Relator term | Examination Committee |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Bhattacharya, Sribas C., |
| Relator term | Examination Committee |
| 710 2# - ADDED ENTRY--CORPORATE NAME | |
| Corporate name or jurisdiction name as entry element | H.M. Thailand King's Scholarship, |
| Relator term | Scholarship Donor |
| 810 2# - SERIES ADDED ENTRY--CORPORATE NAME | |
| Corporate name or jurisdiction name as entry element | Asian Institute of Technology. |
| Title of a work | Thesis ; |
| Volume/sequential designation | no. ET-94-4 |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Materials specified | Full-Text |
| Uniform Resource Identifier | <a href=" http://203.159.5.9/ait-thesis/detail.php?q=B16219"> http://203.159.5.9/ait-thesis/detail.php?q=B16219</a> |
| 907 ## - LOCAL DATA ELEMENT G, LDG (RLIN) | |
| a | .b11407712 |
| b | mnait |
| c | x |
| 902 ## - LOCAL DATA ELEMENT B, LDB (RLIN) | |
| a | 250327 |
| 998 ## - LOCAL CONTROL INFORMATION (RLIN) | |
| Operator's initials, OID (RLIN) | 2 |
| Cataloger's initials, CIN (RLIN) | 951104 |
| First date, FD (RLIN) | m |
| -- | a |
| -- | x |
| -- | 0 |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnait |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnait |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnarc |
| 945 ## - LOCAL PROCESSING INFORMATION (OCLC) | |
| l | mnarc |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | 20-AIT Publication |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | 40-Archives |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050003107207 |
| CREATED | CREATED : 1994-07-06 |
| RECORD Id | RECORD # : i11650734 |
| LPATRON | LPATRON : 1018718 |
| LCHKIN | LCHKIN : 2006-09-17 |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 2 |
| -- | TOT RENEW : 0 |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050003107199 |
| CREATED | CREATED : 1994-07-06 |
| RECORD Id | RECORD # : i11650746 |
| LPATRON | LPATRON : 1016614 |
| LCHKIN | LCHKIN : 2005-04-02 |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 5 |
| -- | TOT RENEW : 21 |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050120367312 |
| CREATED | CREATED : 2016-06-13 |
| RECORD Id | RECORD # : i13033177 |
| LPATRON | LPATRON : 0 |
| LCHKIN | LCHKIN : - |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 0 |
| -- | TOT RENEW : 0 |
| 909 ## - LOCAL ITEMS USED | |
| Barcode | Barcode : 30050120933592 |
| CREATED | CREATED : 2019-11-28 |
| RECORD Id | RECORD # : i13234341 |
| LPATRON | LPATRON : 0 |
| LCHKIN | LCHKIN : - |
| RENEWALS | # RENEWALS : 0 |
| -- | # OVERDUE : 0 |
| -- | IUSE3 : 0 |
| -- | TOT CHKOUT : 0 |
| -- | TOT RENEW : 0 |
| Withdrawn status | Lost status | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type | Cost, normal purchase price |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | AIT Publications | 18/08/2026 | AIT Thesis no. ET-94-4 | 30050003107207 | 18/08/2026 | 1 | 18/08/2026 | 20-AIT Publication | |||||
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | AIT Publications | 18/08/2026 | AIT Thesis no. ET-94-4 | 30050003107199 | 18/08/2026 | 2 | 18/08/2026 | 20-AIT Publication | |||||
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | Archives | 18/08/2026 | AIT Thesis no. ET-94-4 | 30050120367312 | 18/08/2026 | 18/08/2026 | 40-Archives | ||||||
| Available for Loans | Asian Institute of Technology Library | Asian Institute of Technology Library | Archives | 18/08/2026 | AIT Thesis no. ET-94-4 | 30050120933592 | 18/08/2026 | 3 | 18/08/2026 | 20-AIT Publication | 50.00 |

AI Search