Assessment of electricity use for water supply systems in Hatay Province, Vietnam (Record no. 9077)

MARC details
000 -LEADER
fixed length control field 03924nas a2200457 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817163540.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 071116s2007 th uu|m rtt 0| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b12024739
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.WM-06-6
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Bui Phuong Nam
245 10 - TITLE STATEMENT
Title Assessment of electricity use for water supply systems in Hatay Province, Vietnam
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani, Thailand :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2007
300 ## - PHYSICAL DESCRIPTION
Extent 92 leaves :
Other physical details ill.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. WM-06-6
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Water Engineering and Management
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 2007
520 ## - SUMMARY, ETC.
Summary, etc. Water and energy are two highly interconnected sectors and therefore it is good practice to manage them together rather than in isolation. Many research advised that we could save energy, if we save water. In Vietnam, water and energy are currently under severe stress from widespread overuse and pollution caused by the combination of population growth, increased economic activities and inadequate management policies. Hatay is a Red River delta province, bordering with the capital city, Hanoi. Hatay has many favorable conditions for the development of agriculture, industry, tourism and services. It is also one of the provinces in the country having very developed systems of transportation, telecommunication, power and water supply, etc. The main objective of the present study is to analyze the energy intensity of water supply pumps and the relation between water used and electricity required for water supply systems. The study considers three sectors of water use namely Urban, Agricultural and Industrial sectors of Hatay province, Vietnam. Two systems for the urban sector; three systems for the agricultural sector; and eight systems for the industrial sectors are selected for study. The results show that the electricity intensity based on water use was lowest in the agricultural water supply (0.085kWh/m3-0.137kWh/m3) followed by the urban water supply (0.54kWh/m3 - 0.55kWh/m3) and highest in the industrial water supply (0.78kWh/m3- 0.85kWh/m3). Moreover, it is very low in surface water pump systems and high in groundwater sources. The water-use efficiency and benefit-cost analysis are used as a basis of recommendation to the responsible organization for achieving lower electricity intensity.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Municipal water supply
General subdivision Evaluation
Geographic subdivision Vietnam
-- Hatay
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Water-supply
General subdivision Evaluation
Geographic subdivision Vietnam
-- Hatay
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric power consumption
General subdivision Evaluation
Geographic subdivision Vietnam
-- Hatay
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Babel, Mukand Singh,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Gupta, Ashim Das,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Clemente, Roberto S.,
Relator term Examination Committee
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sutat Weesakul,
Relator term Examination committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Electricity of Vietnam (EVN),
Relator term Scholarship Donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element AIT Fellowship,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. WM-06-6
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B11471">http://203.159.5.9/ait-thesis/detail.php?q=B11471</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b12024739
b mnait
c u
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240401
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 071116
First date, FD (RLIN) m
-- a
-- u
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120550636
CREATED CREATED : 2006-06-19
RECORD Id RECORD # : i1254601x
LPATRON LPATRON : 1020964
LCHKIN LCHKIN : 2012-09-28
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 5
-- TOT RENEW : 6
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120550610
CREATED CREATED : 2006-06-19
RECORD Id RECORD # : i12546021
LPATRON LPATRON : 1020176
LCHKIN LCHKIN : 2009-07-02
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 2
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120233472
CREATED CREATED : 2016-01-04
RECORD Id RECORD # : i12920964
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.WM-06-6 30050120550636 17/08/2026 1 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.WM-06-6 30050120550610 17/08/2026 2 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026     AIT Thesis no.WM-06-6 30050120233472 17/08/2026   17/08/2026 40-Archives
คัดลอกแล้ว!