Assessment of the validity and potential usefulness of the non-linear Saunier model in predicting thermal solar collectors performance (Record no. 9511)

MARC details
000 -LEADER
fixed length control field 03271nam a2200409 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817163717.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 080998 th eng
035 ## - SYSTEM CONTROL NUMBER
System control number .b10099633
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no. ET-81-13
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Ang, Koo Soon
245 10 - TITLE STATEMENT
Title Assessment of the validity and potential usefulness of the non-linear Saunier model in predicting thermal solar collectors performance
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1981
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 62 p.
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-81-13
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 1981
520 ## - SUMMARY, ETC.
Summary, etc. This study is concerned with the assessment of the validity and potential usefulness of the Non-Linear Saunier 's model . After having briefly summarized the equations and formulae of the model, and approximations are made for the effective transmittance absorptance product as well as for the effective environment temperature. In addition, an outline of the computer program which has been developed to compute the significant intrinsic parameters from the experimental data is presented. Tests based on the thermal performance of five computer simulated hypothetical(3) and three commercial(4) solar collectors, show that the Non-Linear Saunier ' s Model described adequately the influences of the fluid temperature, the wind speed of the surrounding , and the surrounding infra-red and the solar radiation fluxes on the collector performance. Furthermore it is shown that the significant intrinsic parameters of t he model can be determined by fitting the performance curve of the model with very few experimental data obtained at the two end conditions (i.e. at T-f close to Ta and stagnation conditions) without affecting the accuracy of the model. Hence a much simplified and less time consuming experimental test procedure for characterizing thermal solar collectors can be proposed .
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Solar collectors
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Saunier, G.Y.,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Exell, Robert H.B., Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Walter, Despiegelaere, Ir.,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Government of Federal Republic of Germany,
Relator term Scholarship Donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-81-13
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B21581">http://203.159.5.9/ait-thesis/detail.php?q=B21581</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b10099633
b mnait
c x
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 250103
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 2
Cataloger's initials, CIN (RLIN) 951012
First date, FD (RLIN) m
-- a
-- x
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003103347
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i10110318
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050003103321
CREATED CREATED : 1995-10-13
RECORD Id RECORD # : i1011032x
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120352306
CREATED CREATED : 2016-10-06
RECORD Id RECORD # : i13031983
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 10.00   AIT Thesis no. ET-81-13 30050003103347 17/08/2026 1 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 10.00   AIT Thesis no. ET-81-13 30050003103321 17/08/2026 2 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026     AIT Thesis no. ET-81-13 30050120352306 17/08/2026   17/08/2026 40-Archives
คัดลอกแล้ว!