PVD improvement of reconstituted soft clay with and without electro-osmotic consolidation (Record no. 96353)

MARC details
000 -LEADER
fixed length control field 03190nam a2200397 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818175202.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 040998 th eng
035 ## - SYSTEM CONTROL NUMBER
System control number .b11723622
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no. GE-97-04
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Patawaran, Ma. Aries B.
245 10 - TITLE STATEMENT
Title PVD improvement of reconstituted soft clay with and without electro-osmotic consolidation
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 1998
300 ## - PHYSICAL DESCRIPTION
Extent 83 leaves
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. GE-97-04
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Civil Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 1998
520 ## - SUMMARY, ETC.
Summary, etc. The effect of prefabricated vertical drains (PVD) with and without electro-osmosis on reconstituted soil was investigated. The effect of increasing surcharge while maintaining the same voltage gradient was also examined. The test was conducted on reconstituted soil from AIT. An initial 50 KPa pressure was applied until 90% consolidation. Prefabricated drains L:Ut to 20m::n width were then installed at 20cm spacing in a square pattern. The load was increased to 75 KPa and the effect of the drains was observed. Afterwards, electro-osmosis was applied using a voltage gradient of 80 V /m while maintaining the same overburden pressure . The surcharge was then increased to 82.5 KPa while the voltage gradient remained constant. Test results indicate that the reduction in the water content of the soil was almost the same for both PVD with and without electro-osmosis. An increase in the overburden pressure however, can triple the moisture reduction. Application of electro-osmosis brought about an increase in the shear strength at the anodes. Larger settlements and smaller differential settlements under higher overburden pressures was observed with bigger values occurring at the anodes. An increase in the liquid and plastic limit was also discovered. It was also found out that there is a decrease in the void ratio of the soil with higher values observed at the anodes than at the cathodes.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Vertical drains
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Soil consolidation test
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Bergado, Dennes T.,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Balasubramaniam, A.S.,
Relator term Examination Committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Guey, Lin Der,
Relator term Examination committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology Partial Scholarship,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. GE-97-04
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B12762">http://203.159.5.9/ait-thesis/detail.php?q=B12762</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b11723622
b mnait
c x
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240614
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 980904
First date, FD (RLIN) m
-- a
-- x
-- 0
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120717748
CREATED CREATED : 1997-07-04
RECORD Id RECORD # : i12091170
LPATRON LPATRON : 1033413
LCHKIN LCHKIN : 2024-12-06
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 2
-- TOT CHKOUT : 18
-- TOT RENEW : 23
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160081021
CREATED CREATED : 2016-05-17
RECORD Id RECORD # : i12980353
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026   AIT Thesis no. GE-97-04 30050120717748 18/08/2026 1 18/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026   AIT Thesis no. GE-97-04 30050160081021 18/08/2026 1 18/08/2026 40-Archives
คัดลอกแล้ว!