The assessment of the distribution network and power supply of Sihanoukville

By: Call Number: AIT RSPR no. ET-96-1 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Research studies project report ; no. ET-96-1Publication details: Bangkok : Asian Institute of Technology, 1996Description: 74 leavesSubject(s): Online resources: Dissertation note: Research Studies Project Report (M.Eng.) - Asian Institute of Technology, 1996 Summary: This research study has been written to survey load consumption for the consumers as: residential consumer, commercial consumer, industrial consumer, governmental agencies, and public consumer. Load demand reserve for load growth 10 % from 1996 to 2009. The design of distribution system consider about the supplying electricity to the customers by some characteristics, cross section of conductors, power loss, voltage drop. To compare those characteristics between 6.3 kV, 22 kV, and 44 kV which voltage level is better. The improving of power factor from 0.8 to 0.9 by selecting capacitor banks to reduce the reactive power. Furthermore the future expansion and operation and maintenance are studied. Also consider about the economic evaluation for selecting the best of three voltage levels by comparing some characteristics above. Finally the environment domain is focused by considering the visual impact, social impact and health impact.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no. ET-96-1 (Browse shelf(Opens below)) 1 Available 30050120614531
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no. ET-96-1 (Browse shelf(Opens below)) 2 Available 30050120614523
40-Archives Asian Institute of Technology Library Archives AIT RSPR no. ET-96-1 (Browse shelf(Opens below)) Available 30050160015383

A research study in partial fulfillment of the requirements for the degree of Master of Engineering

Research Studies Project Report (M.Eng.) - Asian Institute of Technology, 1996

This research study has been written to survey load consumption for the consumers as: residential consumer, commercial consumer, industrial consumer, governmental agencies, and public consumer. Load demand reserve for load growth 10 % from 1996 to 2009. The design of distribution system consider about the supplying electricity to the customers by some characteristics, cross section of conductors, power loss, voltage drop. To compare those characteristics between 6.3 kV, 22 kV, and 44 kV which voltage level is better. The improving of power factor from 0.8 to 0.9 by selecting capacitor banks to reduce the reactive power. Furthermore the future expansion and operation and maintenance are studied. Also consider about the economic evaluation for selecting the best of three voltage levels by comparing some characteristics above. Finally the environment domain is focused by considering the visual impact, social impact and health impact.