Construction of an original test bed for evaluating solar collector performance non-linearly
Call Number: AIT Thesis no. ET-81-11 Material type:
TextSeries: Asian Institute of Technology. Thesis ; no. ET-81-11Publication details: Bangkok : Asian Institute of Technology, 1981Description: xi, 55 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1981 Summary: Testing of solar collectors following the standard methods is time consuming . The performance of the collector resulted from data assessment through linear regression method providing by t he manufacture is not correct if the working conditions are different from the test conditions. Professor G.Y. Saunier has proposed his non- linear model applied to any working condition. Two test beds were constructed in order to determine t he intrinsic parameters needed . Three kinds of commercial collectors were tested and the error of the results and instruments used were analyzed statistically. It was shown that the accuracy of differential temperature measuring device was not high enough so that the large error happened at low water temperature . The new method of determing back and side loss coefficient of the collector was suggested and some problems in t he experimental work were discussed.
| Cover image | Item type | Current library | Home library | Collection | Shelving location | Call number | Materials specified | Vol info | URL | Copy number | Status | Notes | Date due | Barcode | Item holds | Item hold queue priority | Course reserves | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no. ET-81-11 (Browse shelf(Opens below)) | 1 | Available | 30050003103297 | |||||||||||||
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no. ET-81-11 (Browse shelf(Opens below)) | 2 | Available | 30050003103289 | |||||||||||||
40-Archives
|
Asian Institute of Technology Library Archives | AIT Thesis no. ET-81-11 (Browse shelf(Opens below)) | Available | 30050120352280 |
A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
Thesis (M.Eng.) - Asian Institute of Technology, 1981
Testing of solar collectors following the standard methods is time consuming . The performance of the collector resulted from data assessment through linear regression method providing by t he manufacture is not correct if the working conditions are different from the test conditions. Professor G.Y. Saunier has proposed his non- linear model applied to any working condition. Two test beds were constructed in order to determine t he intrinsic parameters needed . Three kinds of commercial collectors were tested and the error of the results and instruments used were analyzed statistically. It was shown that the accuracy of differential temperature measuring device was not high enough so that the large error happened at low water temperature . The new method of determing back and side loss coefficient of the collector was suggested and some problems in t he experimental work were discussed.