Design and operation of on-farm storage facilities for demand oriented irrigation scheme

By: Call Number: AIT Thesis no.WA-90-24 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. WA-90-24Publication details: Bangkok : Asian Institute of Technology, 1990Description: 115 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1990 Summary: In irrigation systems, water demand usually shows large fluctuations due to rain, crop growth, non-availability of labor etc., which water supply can not follow. It may lead to over- and under- irrigation and result in low water use efficiency, Hence irrigation system should be designed to satisfy fluctuating water demand and at the same time prevent invalid overflow. On-farm storage facilities are expected to be useful for this purpose. In this study irrigation system is assumed to consist of an intermediate reservoir (regulating reservoir, IR) and a chain of internal water storage facilities (farm ponds, FP). The purpose of a farm pond is to smoothen daily fluctuations whereas an intermediate reservoir balances seasonal fluctuations of irrigation water demand. The FP model was developed for determination of storage capacity and operation rule of a farm pond, at various conditions such as cropping pattern, area of command, hourly irrigation demand, and at various reliability levels. For operation of farm pond four operating rules were formulated and out of them best one was selected for the present study. The IR model was also developed for determination of storage capacity of intermediate reservoir at various reliability levels. These FP and IR models were applied to Mae-Taeng Irrigation Project in Chiang Mai Province, Thailand. The storage capacities of farm ponds and intermediate reservoir were determined under various cropping patterns, hourly demand patterns, for various reliability levels. It was confirmed that both farm pond and intermediate reservoir can increase water use efficiency and decrease deficit. It was also observed that a good operating rule can give less required storage capacity. It was found that storage capacity of farm pond is governed by both wet and dry season crops. For various parameters of ARMA model for generation of water demand, about 5 to 10% variation in the storage capacity was observed. However 10 to 20% variation in storage capacity was observed due to hourly demand variatio
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.WA-90-24 (Browse shelf(Opens below)) 3 Available 30050120574149
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.WA-90-24 (Browse shelf(Opens below)) Available 30050160033782

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology

Thesis (M.Eng.) - Asian Institute of Technology, 1990

In irrigation systems, water demand usually shows large fluctuations due to rain, crop growth, non-availability of labor etc., which water supply can not follow. It may lead to over- and under- irrigation and result in low water use efficiency, Hence irrigation system should be designed to satisfy fluctuating water demand and at the same time prevent invalid overflow. On-farm storage facilities are expected to be useful for this purpose. In this study irrigation system is assumed to consist of an intermediate reservoir (regulating reservoir, IR) and a chain of internal water storage facilities (farm ponds, FP). The purpose of a farm pond is to smoothen daily fluctuations whereas an intermediate reservoir balances seasonal fluctuations of irrigation water demand. The FP model was developed for determination of storage capacity and operation rule of a farm pond, at various conditions such as cropping pattern, area of command, hourly irrigation demand, and at various reliability levels. For operation of farm pond four operating rules were formulated and out of them best one was selected for the present study. The IR model was also developed for determination of storage capacity of intermediate reservoir at various reliability levels. These FP and IR models were applied to Mae-Taeng Irrigation Project in Chiang Mai Province, Thailand. The storage capacities of farm ponds and intermediate reservoir were determined under various cropping patterns, hourly demand patterns, for various reliability levels. It was confirmed that both farm pond and intermediate reservoir can increase water use efficiency and decrease deficit. It was also observed that a good operating rule can give less required storage capacity. It was found that storage capacity of farm pond is governed by both wet and dry season crops. For various parameters of ARMA model for generation of water demand, about 5 to 10% variation in the storage capacity was observed. However 10 to 20% variation in storage capacity was observed due to hourly demand variatio

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!