Determination of optimum operating conditions of baffled septic tank systems treating blackwater
Call Number: AIT Thesis no.EV-04-19 Material type:
SeriesSeries: Asian Institute of Technology. Thesis ; no. EV-04-19Publication details: Pathum Thani, Thailand : Asian Institute of Technology, 2004Description: 125 leaves : illSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 2004 Summary: This study was conducted to determine the optimum organic loading rate (OLR) and effects of linear alkyl sulfonate (LAS) in the baffled septic tank systems treating blackwater. For determination of the optimum OLR, four laboratory-scale baffled septic tank units, made of acrylic plastic with dimensions of 0.25x0.4x0.64 m3 (width x height x length), were operated at the OLR of 0.5-1.25 g COD/(L.d). The wastewater was a mixture of septage and domestic wastewater. It was found that the removal efficiencies of baffled septic tank systems in terms of COD, BOD, and TS would increase with the increase of OLR at the magnitudes of greater than 80%, 70%, and 60%, respectively. Because clogging problems have been found in the laboratory-scale units operating at the highest OLR of 1.25 g COD/(L.d), the optimum OLR should be 1 g COD/(L.d). In addition, the investigations of treatment performance indicated that a septic tank with tlu·ee baffles (R.2) was the best as compared to other units. For investigations of the LAS effects, the laboratory-scale units were operated at the OLR of 1 g COD/(L.d) and fed with LAS of 0.5-1.0 g. It was found that the removal efficiencies of septic tank with three baffles (R.2) and septic tank with two baffles and anaerobic media (R.4) in terms of COD, TS, and TSS would have no effect with the increase of LAS loading. A conventional septic tank (R.1) or a septic tank with two baffles (R.3), the removal efficiencies in term of COD, TS, and TSS would increase with the increase of LAS loading, and be greater than 85%, 70%, and 85%, respectively. Based on fluorescence in situ hybridization (FISH) analysis, it was found that the percent of bacterial and archaeal communities of baffled septic tank systems were equal to 22.5% and 5%, respectively, at OLR of 0.5 - 1.25 g COD/(L.d). Both percent of bacterial and archaeal communities would likely increase with the increase of LAS loading.
| Cover image | Item type | Current library | Home library | Collection | Shelving location | Call number | Materials specified | Vol info | URL | Copy number | Status | Notes | Date due | Barcode | Item holds | Item hold queue priority | Course reserves | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no.EV-04-19 (Browse shelf(Opens below)) | 1 | Available | 30050120706345 | |||||||||||||
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no.EV-04-19 (Browse shelf(Opens below)) | 2 | Available | 30050120706337 | |||||||||||||
40-Archives
|
Asian Institute of Technology Library Archives | AIT Thesis no.EV-04-19 (Browse shelf(Opens below)) | Available | 30050160050893 |
A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
Thesis (M.Eng.) - Asian Institute of Technology, 2004
This study was conducted to determine the optimum organic loading rate (OLR) and effects of linear alkyl sulfonate (LAS) in the baffled septic tank systems treating blackwater. For determination of the optimum OLR, four laboratory-scale baffled septic tank units, made of acrylic plastic with dimensions of 0.25x0.4x0.64 m3 (width x height x length), were operated at the OLR of 0.5-1.25 g COD/(L.d). The wastewater was a mixture of septage and domestic wastewater. It was found that the removal efficiencies of baffled septic tank systems in terms of COD, BOD, and TS would increase with the increase of OLR at the magnitudes of greater than 80%, 70%, and 60%, respectively. Because clogging problems have been found in the laboratory-scale units operating at the highest OLR of 1.25 g COD/(L.d), the optimum OLR should be 1 g COD/(L.d). In addition, the investigations of treatment performance indicated that a septic tank with tlu·ee baffles (R.2) was the best as compared to other units. For investigations of the LAS effects, the laboratory-scale units were operated at the OLR of 1 g COD/(L.d) and fed with LAS of 0.5-1.0 g. It was found that the removal efficiencies of septic tank with three baffles (R.2) and septic tank with two baffles and anaerobic media (R.4) in terms of COD, TS, and TSS would have no effect with the increase of LAS loading. A conventional septic tank (R.1) or a septic tank with two baffles (R.3), the removal efficiencies in term of COD, TS, and TSS would increase with the increase of LAS loading, and be greater than 85%, 70%, and 85%, respectively. Based on fluorescence in situ hybridization (FISH) analysis, it was found that the percent of bacterial and archaeal communities of baffled septic tank systems were equal to 22.5% and 5%, respectively, at OLR of 0.5 - 1.25 g COD/(L.d). Both percent of bacterial and archaeal communities would likely increase with the increase of LAS loading.
There are no comments on this title.

AI Search