Dynamic behaviour of 200 MW-turbo-generator foundation at South Bangkok Thermal Plant: comparison between measured and predicted behaviour

By: Call Number: AIT Thesis no. 773 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. 773Publication details: Bangkok : Asian Institute of Technology, 1975Description: 87 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1975 Summary: Measurements were performed on a 200 MW turbo-generator foundation at South Bangkok Thermal Plant in order to study its dynamic performance and comparing it with the theoretically predictable behavior. The factor of primary interest which must be known in theoretical analysis is the shear modulus of the roil. For this purpose cross-hole shooting was carried out near the turbine foundation in order to determine the in-situ shear wave velocity as a function of depth. The measurements showed that the vibration of the turbine foundation is very complex. It consisted of flexural vibration of the beams and torsional vibration of the upper slab associated with horizontal vibration. The measured amplitude of vibration compared with the predicted value gave a fairly good agreement. However, it was found that the natural frequencies of the system could not be found accurately.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. 773 (Browse shelf(Opens below)) 2 Available 30050003035564
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. 773 (Browse shelf(Opens below)) 1 Available 30050120138911
40-Archives Asian Institute of Technology Library Archives AIT Thesis no. 773 (Browse shelf(Opens below)) Available 30050160092515

A thesis submitted in partial fulfilment of the requirements for the degree of Master of Engineering at the Asian Institute of Technology, Bangkok, Thailand .

Thesis (M.Eng.) - Asian Institute of Technology, 1975

Measurements were performed on a 200 MW turbo-generator foundation at South Bangkok Thermal Plant in order to study its dynamic performance and comparing it with the theoretically predictable behavior. The factor of primary interest which must be known in theoretical analysis is the shear modulus of the roil. For this purpose cross-hole shooting was carried out near the turbine foundation in order to determine the in-situ shear wave velocity as a function of depth. The measurements showed that the vibration of the turbine foundation is very complex. It consisted of flexural vibration of the beams and torsional vibration of the upper slab associated with horizontal vibration. The measured amplitude of vibration compared with the predicted value gave a fairly good agreement. However, it was found that the natural frequencies of the system could not be found accurately.