Energy analysis in Bumrungrad hospital

By: Call Number: AIT RSPR no. ET-85-6 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Research studies project report ; no. ET-85-6Publication details: Bangkok : Asian Institute of Technology, 1985Description: 104 pSubject(s): Online resources: Dissertation note: Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1985 Summary: A study on energy uses of bumrungrad Hospital, a 200-bed private hospital in Bangkok, has been carried out. Energy audit of various energy systems, such as electrical system, air conditioning system and steam production system have been made. The total energy consumption of the hospital was approximately 1.64 million MJ and costed about 5.84 million Bahts in 1984. It consumed 60.4 % and 39.6 % of electricity and diesel oil by quantity or 81.0 % and 19.0% by cost , respectively. Thermal energy systems which are the steam production system and the air conditioning system costed practically 62 % of the total energy bill. The energy and availability analyses are used to identify the locations, types and true magnitudes of wasted resource, reversible and irreversible losses from the thermal energy systems. Energy conservation opportunities in the thermal energy systems are identified, analyzed, and recommended. Economic returns of the potential conservation measures are also analyzed. The Saving that may be feasible from the recommended measures can be at least 42370 Bahts/year, or about 7.3 % of the total energy cost in 1984. A higher saving is also possible by incorporating good energy management along with the recommended measures.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT RSPR no. ET-85-6 (Browse shelf(Opens below)) 3 Available 30050120615140
40-Archives Asian Institute of Technology Library Archives AIT RSPR no. ET-85-6 (Browse shelf(Opens below)) Available 30050160016449

A research study summitted in partial fulfilment of the requirements for the Degree of Master of Engineering, School of Environment, Resources and Development

Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1985

A study on energy uses of bumrungrad Hospital, a 200-bed private hospital in Bangkok, has been carried out. Energy audit of various energy systems, such as electrical system, air conditioning system and steam production system have been made. The total energy consumption of the hospital was approximately 1.64 million MJ and costed about 5.84 million Bahts in 1984. It consumed 60.4 % and 39.6 % of electricity and diesel oil by quantity or 81.0 % and 19.0% by cost , respectively. Thermal energy systems which are the steam production system and the air conditioning system costed practically 62 % of the total energy bill. The energy and availability analyses are used to identify the locations, types and true magnitudes of wasted resource, reversible and irreversible losses from the thermal energy systems. Energy conservation opportunities in the thermal energy systems are identified, analyzed, and recommended. Economic returns of the potential conservation measures are also analyzed. The Saving that may be feasible from the recommended measures can be at least 42370 Bahts/year, or about 7.3 % of the total energy cost in 1984. A higher saving is also possible by incorporating good energy management along with the recommended measures.

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!