Energy conservation in a typical Thai hotel in Bangkok

By: Call Number: AIT RSPR no. ET-84-4 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Research studies project report ; no. ET-84-4Publication details: Bangkok : Asian Institute of Technology, 1984Description: 75 pSubject(s): Online resources: Dissertation note: Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1984 Summary: This research is an attempt to investigate the possibility of energy conservation especially for mechanical systems in the Sheraton Hotel. Breakdowns of energy consumption of various energy systems such as the air-conditioning system and steam system have been done. Energy auditing has been carried out, thermal performance of the air-conditioning system and boilers have been analyzed. Energy conservation opportunities in various energy system are analyzed and recommended. The economic analysis of such conservation opportunities is studied using the pay back period and rate of return. The possible savings from the recommended measures can be about 4,865,000 baht/year of about 44% of the total hotel energy consumption in 1983.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no. ET-84-4 (Browse shelf(Opens below)) 1 Available 30050003121794
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no. ET-84-4 (Browse shelf(Opens below)) 2 Available 30050003121802
40-Archives Asian Institute of Technology Library Archives AIT RSPR no. ET-84-4 (Browse shelf(Opens below)) Available 30050120239602

A research study submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development

Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1984

This research is an attempt to investigate the possibility of energy conservation especially for mechanical systems in the Sheraton Hotel. Breakdowns of energy consumption of various energy systems such as the air-conditioning system and steam system have been done. Energy auditing has been carried out, thermal performance of the air-conditioning system and boilers have been analyzed. Energy conservation opportunities in various energy system are analyzed and recommended. The economic analysis of such conservation opportunities is studied using the pay back period and rate of return. The possible savings from the recommended measures can be about 4,865,000 baht/year of about 44% of the total hotel energy consumption in 1983.

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!