Finite element modelling of groundwater aquifer system in Hanoi territory, Vietnam
Call Number: AIT Thesis no.GT-92-18 Material type:
TextSeries: Asian Institute of Technology. Thesis ; no. GT-92-18Publication details: Bangkok : Asian Institute of Technology, 1993Description: 106 leaves + 1 online resourceSubject(s): Online resources: Dissertation note: Thesis (M.Sc.) - Asian Institute of Technology, 1993 Summary: The main source of water supply for the domestic and industrial use of Hanoi-City, the Capital of Vietnam, comes from groundwater. The water demand is increasing all the time. The present total water withdrawal is 467, 540 m2/day. By the year of 2000 the city's water demand is predicted to be 941,000 m2/day. The final aim of the work is to determine whether the water withdrawal of this quantity would be extracted reliably and what would be the groundwater level with this water exploitation process. The finite element modeling has been carried out first time for Hanoi aquifer system. The aquifer has been considered as a two dimensional leaky confined aquifer. The leakage through the confining layer was represented by the difference in the groundwater level s of the unconfined and confined aquifers, the leakance of the confining layer or that of the unconfined aquifer. The model parameters have been calibrated by an inverse analysis method: method incorporating the observation and prior information to get the best model parameters. The model has been applied to predict the water level distribution of the confined aquifer when the total water withdrawal is taken equal the predicted water demand of the city by the year of 2000. The predicted head shows that this water withdrawal is permitted from the criterion of allowable groundwater level for the aquifer system.
| Cover image | Item type | Current library | Home library | Collection | Shelving location | Call number | Materials specified | Vol info | URL | Copy number | Status | Notes | Date due | Barcode | Item holds | Item hold queue priority | Course reserves | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no.GT-92-18 (Browse shelf(Opens below)) | 1 | Available | 30050003018339 | |||||||||||||
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no.GT-92-18 (Browse shelf(Opens below)) | 2 | Available | 30050120712913 | |||||||||||||
40-Archives
|
Asian Institute of Technology Library Archives | AIT Thesis no.GT-92-18 (Browse shelf(Opens below)) | 1 | Available | 30050120308563 | |||||||||||||
20-AIT Publication
|
Asian Institute of Technology Library Archives | AIT Thesis no.GT-92-18 (Browse shelf(Opens below)) | 3 | Available | 30050120929418 |
A research study submitted in partial fulfillment of the requirements for the degree of Master of Science, School of Engineering and Technology
Thesis (M.Sc.) - Asian Institute of Technology, 1993
The main source of water supply for the domestic and industrial use of Hanoi-City, the Capital of Vietnam, comes from groundwater. The water demand is increasing all the time. The present total water withdrawal is 467, 540 m2/day. By the year of 2000 the city's water demand is predicted to be 941,000 m2/day. The final aim of the work is to determine whether the water withdrawal of this quantity would be extracted reliably and what would be the groundwater level with this water exploitation process. The finite element modeling has been carried out first time for Hanoi aquifer system. The aquifer has been considered as a two dimensional leaky confined aquifer. The leakage through the confining layer was represented by the difference in the groundwater level s of the unconfined and confined aquifers, the leakance of the confining layer or that of the unconfined aquifer. The model parameters have been calibrated by an inverse analysis method: method incorporating the observation and prior information to get the best model parameters. The model has been applied to predict the water level distribution of the confined aquifer when the total water withdrawal is taken equal the predicted water demand of the city by the year of 2000. The predicted head shows that this water withdrawal is permitted from the criterion of allowable groundwater level for the aquifer system.