Analysis of air pollution in coal-fired thermal power plants in Vietnam : case study of Vinh Tan 3 Thermal Power Plant

By: Call Number: AIT RSPR no.EV-12-07 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Research studies project report ; no. EV-12-07Publication details: Pathum Thani : Asian Institute of Technology, 2012Description: 63 leaves : ill., chartsSubject(s): Online resources: Dissertation note: Research Studies Project Report (M.Eng.) - Asian Institute of Technology, 2012 Summary: The rapid increase of coal-fired thermal power plants (TPPs) in Vietnam recent years leads to the increased emission of the combustion related pollutants. It is important to understand how these pollutants from coal-fired thermal power plants disperse in the ambient atmosphere. This study examines the air pollution condition at a proposed TPP and applies an air quality model, the EPA approved dispersion model of AERMOD,to predict the ambient air pollution concentrations resulted from different emission scenarios. The stack emission rates from the power plant were calculated to provide the input emission data for the modeling. The meteorology data were taken from MM5 model, the prognostic meteorology model for 2008 year.Ground level concentrations of pollutants including oxides of nitrogen (NOx), oxides of sulfur (SOx),particulate matter (PM) were estimated by the model under three fuel-control devices scenarios. The results show that if coal is used as the main fuel with the control devices of ESP,Sea-water FGD and Low NOx Burner then only PM10 and SO2 would meet the Vietnamese national ambient air quality standards and WHO ambient air quality guidelines. Only when SCR is installed for NOx emission control are all 3 pollutants would meet the standards. If natural gasis used as the main fuel in combination with low-NOx burner then the emission of PM10 and SO2 would largely eliminated. The ambient air levels of all 3 pollutants would be well below the standards. Under all 3 scenarios the levels simulated for the populated areas and sensitive areas were found below the standards suggesting insignificant impacts from the proposed power plant. The model results under different emission scenarios can serve as the basis to suggest the emission control measures to improve the air quality in the study area
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no.EV-12-07 (Browse shelf(Opens below)) 1 Available 30050120613012
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no.EV-12-07 (Browse shelf(Opens below)) 2 Available 30050120613004
40-Archives Asian Institute of Technology Library Archives AIT RSPR no.EV-12-07 (Browse shelf(Opens below)) Available 30050120220131

A research study submitted in partial fulfillmentof the requirements for the degree of Master of Engineering (Professional)inEnvironmental Engineering and Management

Research Studies Project Report (M.Eng.) - Asian Institute of Technology, 2012

The rapid increase of coal-fired thermal power plants (TPPs) in Vietnam recent years leads to the increased emission of the combustion related pollutants. It is important to understand how these pollutants from coal-fired thermal power plants disperse in the ambient atmosphere. This study examines the air pollution condition at a proposed TPP and applies an air quality model, the EPA approved dispersion model of AERMOD,to predict the ambient air pollution concentrations resulted from different emission scenarios. The stack emission rates from the power plant were calculated to provide the input emission data for the modeling. The meteorology data were taken from MM5 model, the prognostic meteorology model for 2008 year.Ground level concentrations of pollutants including oxides of nitrogen (NOx), oxides of sulfur (SOx),particulate matter (PM) were estimated by the model under three fuel-control devices scenarios. The results show that if coal is used as the main fuel with the control devices of ESP,Sea-water FGD and Low NOx Burner then only PM10 and SO2 would meet the Vietnamese national ambient air quality standards and WHO ambient air quality guidelines. Only when SCR is installed for NOx emission control are all 3 pollutants would meet the standards. If natural gasis used as the main fuel in combination with low-NOx burner then the emission of PM10 and SO2 would largely eliminated. The ambient air levels of all 3 pollutants would be well below the standards. Under all 3 scenarios the levels simulated for the populated areas and sensitive areas were found below the standards suggesting insignificant impacts from the proposed power plant. The model results under different emission scenarios can serve as the basis to suggest the emission control measures to improve the air quality in the study area