Analysis of the 2003 water-distribution system by the EPANET model to serve the Amphur Muang area, Surathani

By: Call Number: AIT RSPR no. EV-03-8 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Research studies project report ; no. EV-03-8Publication details: Pathum Thani, Thailand : Asian Institute of Technology, 2003Description: 54 leavesSubject(s): Online resources: Summary: The PW A is conducting standard quality water; sufficient delivery pressure and extensive coverage of the supply for maintain customer's satisfaction. The customer's satisfaction study is exploring a wide variety of possible factors. Therefore, the author is developing a water-distribution model using the EP ANET software to assist with assessment in the customer's satisfaction study. The results are showing the percentage of water contributed by specific locations in the Amphur Muang area, Suratthani for 2003 conditions. Initially the model was calibrated using the present-day (2003) data collected during summer-demand conditions of April 2003. The model network consists of 1,567 pipe segments ranging in diameter from 100 millimeters (mm) to 900 mm, and 1,434 junctions (nodes). The absolute difference between measured and simulated hourly average pressures for all measurement locations ranges between 0.2-11.9 mwc. The medium pressure differences support the assertion that the model is well calibrated. Besides, it shows a reliable representation of water-distribution system conditions during 2003. In addition, a simulation of the transpott of residual chlorine was conducted and compared with experimental data gathered at 25 discharge points of the water distribution system for April, 2003. A measured concentration of chlorine range was between 0.3-0.5 milligrams per liter (mg/l). The comparison indicates a difference within the range of 0.01- 0.12 mg/l or a mean relative difference of 15.59% with a range of 2-25%. Basically, the model indicates a slightly under prediction. However a correlation coefficient of 0.56 indicates a medium correlation between measured concentrations and simulated values. Therefore, this water-quality simulation is confirming that the model is reasonably calibrated and an acceptable representation of the present-day water-distribution system characteristics.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no. EV-03-8 (Browse shelf(Opens below)) 1 Available 30050120613921
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT RSPR no. EV-03-8 (Browse shelf(Opens below)) 2 Available 30050120613939
40-Archives Asian Institute of Technology Library Archives AIT RSPR no. EV-03-8 (Browse shelf(Opens below)) Available 30050120220347

A research study submitted in partial fulfillment of the requirements for the degree of Master of Engineering (Executive).

The PW A is conducting standard quality water; sufficient delivery pressure and extensive coverage of the supply for maintain customer's satisfaction. The customer's satisfaction study is exploring a wide variety of possible factors. Therefore, the author is developing a water-distribution model using the EP ANET software to assist with assessment in the customer's satisfaction study. The results are showing the percentage of water contributed by specific locations in the Amphur Muang area, Suratthani for 2003 conditions. Initially the model was calibrated using the present-day (2003) data collected during summer-demand conditions of April 2003. The model network consists of 1,567 pipe segments ranging in diameter from 100 millimeters (mm) to 900 mm, and 1,434 junctions (nodes). The absolute difference between measured and simulated hourly average pressures for all measurement locations ranges between 0.2-11.9 mwc. The medium pressure differences support the assertion that the model is well calibrated. Besides, it shows a reliable representation of water-distribution system conditions during 2003. In addition, a simulation of the transpott of residual chlorine was conducted and compared with experimental data gathered at 25 discharge points of the water distribution system for April, 2003. A measured concentration of chlorine range was between 0.3-0.5 milligrams per liter (mg/l). The comparison indicates a difference within the range of 0.01- 0.12 mg/l or a mean relative difference of 15.59% with a range of 2-25%. Basically, the model indicates a slightly under prediction. However a correlation coefficient of 0.56 indicates a medium correlation between measured concentrations and simulated values. Therefore, this water-quality simulation is confirming that the model is reasonably calibrated and an acceptable representation of the present-day water-distribution system characteristics.