Application of ferrocement in low-cost undulated roofing elements
Call Number: AIT Thesis no. ST-79-33 Material type:
TextSeries: Asian Institute of Technology. Thesis ; no. ST-79-33Publication details: Bangkok : Asian Institute of Technology, 1979Description: vii, 57 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.)- Asian Institute of Technology, 1979 Summary: The objective of this study is to study the applicability of the ferrocement folded plate roof panel in the construction of low cost roofs and conduct a comparative study with similar asbestos cement car port tile roof panels. The panel is analyzed by using the classical folded plate technique. Six ferrocement panels were fabricated with two varying parameters viz., type of wire mesh and the amount of reinforcement in transverse direction. The panels were subjected to uniformly distributed load by using sand and deflections were measured along the span length. Test results revealed that the panels using square mesh were stronger than those using hexagonal mesh. The transverse reinforcement had only little effect on the strength of the roof panels. Ferrocement panels were found to be much stronger than asbestos car port tiles with respect to their deflections. The economical evaluation showed that the cost per square meter of roofing area of the asbestos panels were higher than that of the ferrocement panels. It was concluded that the ferrocement folded plate panels ·offer a feasible solution to meet the needs of a strong and durable low-cost roofing in developing countries.
| Cover image | Item type | Current library | Home library | Collection | Shelving location | Call number | Materials specified | Vol info | URL | Copy number | Status | Notes | Date due | Barcode | Item holds | Item hold queue priority | Course reserves | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no. ST-79-33 (Browse shelf(Opens below)) | 2 | Available | 30050003079117 | |||||||||||||
40-Archives
|
Asian Institute of Technology Library Archives | AIT Thesis no. ST-79-33 (Browse shelf(Opens below)) | 1 | Available | 30050160014030 |
A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology
Thesis (M.Eng.)- Asian Institute of Technology, 1979
The objective of this study is to study the applicability of the ferrocement folded plate roof panel in the construction of low cost roofs and conduct a comparative study with similar asbestos cement car port tile roof panels. The panel is analyzed by using the classical folded plate technique. Six ferrocement panels were fabricated with two varying parameters viz., type of wire mesh and the amount of reinforcement in transverse direction. The panels were subjected to uniformly distributed load by using sand and deflections were measured along the span length. Test results revealed that the panels using square mesh were stronger than those using hexagonal mesh. The transverse reinforcement had only little effect on the strength of the roof panels. Ferrocement panels were found to be much stronger than asbestos car port tiles with respect to their deflections. The economical evaluation showed that the cost per square meter of roofing area of the asbestos panels were higher than that of the ferrocement panels. It was concluded that the ferrocement folded plate panels ·offer a feasible solution to meet the needs of a strong and durable low-cost roofing in developing countries.
There are no comments on this title.

AI Search