A multi-objective approach for optimal placement of DG to enhance power distribution network performance using NSPSO
Call Number: AIT Thesis no.ET-13-17 Material type:
SeriesSeries: Asian Institute of Technology. Thesis ; no. ET-13-17Publication details: Pathum Thani, Thailand : Asian Institute of Technology, 2013Description: 36 leaves : ill. + 1 online resourceSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 2013 Summary: The study aims to find the best position and size of multi-type DG in distribution network base on three objective functions: maximize the increasable of load (loading factor), minimize the system real power loss and minimize the investment cost per year. IEEE 33-bus radial distribution system use to test by the NSPSO method to determine location and capacity of a specific number of DG in distribution system. The final optimal solution is compromised by fuzzy method. The optimization problems can separate to three cases by adding multi-type of DG. Case 1 is adding Photovoltaic (PV), Case 2 is adding Micro turbine (MT) and Case 3 is adding both PV and MT. The results of the study show Case 1 is the best plan with 49.61 percent of loading factor and 63.61 percent of system real power loss minimization compare to the base case. For economic planning, Case 3 is the best plan with 0.4238 million $/year of annualized investment cost.
| Cover image | Item type | Current library | Home library | Collection | Shelving location | Call number | Materials specified | Vol info | URL | Copy number | Status | Notes | Date due | Barcode | Item holds | Item hold queue priority | Course reserves | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no.ET-13-17 (Browse shelf(Opens below)) | 1 | Available | 30050120387435 | |||||||||||||
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no.ET-13-17 (Browse shelf(Opens below)) | 2 | Available | 30050120602841 | |||||||||||||
40-Archives
|
Asian Institute of Technology Library Archives | AIT Thesis no.ET-13-17 (Browse shelf(Opens below)) | Available | 30050120367833 |
A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Energy
Thesis (M.Eng.) - Asian Institute of Technology, 2013
The study aims to find the best position and size of multi-type DG in distribution network base on three objective functions: maximize the increasable of load (loading factor), minimize the system real power loss and minimize the investment cost per year. IEEE 33-bus radial distribution system use to test by the NSPSO method to determine location and capacity of a specific number of DG in distribution system. The final optimal solution is compromised by fuzzy method. The optimization problems can separate to three cases by adding multi-type of DG. Case 1 is adding Photovoltaic (PV), Case 2 is adding Micro turbine (MT) and Case 3 is adding both PV and MT. The results of the study show Case 1 is the best plan with 49.61 percent of loading factor and 63.61 percent of system real power loss minimization compare to the base case. For economic planning, Case 3 is the best plan with 0.4238 million $/year of annualized investment cost.