Call Number: AIT Thesis no. 847 Material type:
TextSeries: Asian Institute of Technology. Thesis ; no. 847Publication details: Bangkok : Asian Institute of Technology, 1975Description: 62 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1975 Summary: In this thesis, several proportioning methods for both the normal weight concrete and the light weight concrete have been reviewed. The unit water method is used for normal weight concrete and the ACI method with some modifications is used for light weight concrete. A comparison has been made between two methods based on multifactor optimization principle and on monofactor optimization principle respectively. These two programs are nearly the same from an economic point of view , if the same water cement ratio-strength relationship is used. The information stored in the computer is for a particular aggregate and ordinary Portland cement. Therefore, the program cannot be considered generally applicable for all aggregate and cement types. Because of the lack of information, trial mix adjustment is proposed for strength and workability only; adjustment techniques for volume change, thermal conductivity and sound transmission are recommended for future research.
| Cover image | Item type | Current library | Home library | Collection | Shelving location | Call number | Materials specified | Vol info | URL | Copy number | Status | Notes | Date due | Barcode | Item holds | Item hold queue priority | Course reserves | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no. 847 (Browse shelf(Opens below)) | 1 | Available | 30050003036984 | |||||||||||||
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT Thesis no. 847 (Browse shelf(Opens below)) | 2 | Available | 30050003036976 | |||||||||||||
40-Archives
|
Asian Institute of Technology Library Archives | AIT Thesis no. 847 (Browse shelf(Opens below)) | Available | 30050160091863 |
A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering of the Asian Institute of Technology, Bangkok, Thailand.
Thesis (M.Eng.) - Asian Institute of Technology, 1975
In this thesis, several proportioning methods for both the normal weight concrete and the light weight concrete have been reviewed. The unit water method is used for normal weight concrete and the ACI method with some modifications is used for light weight concrete. A comparison has been made between two methods based on multifactor optimization principle and on monofactor optimization principle respectively. These two programs are nearly the same from an economic point of view , if the same water cement ratio-strength relationship is used. The information stored in the computer is for a particular aggregate and ordinary Portland cement. Therefore, the program cannot be considered generally applicable for all aggregate and cement types. Because of the lack of information, trial mix adjustment is proposed for strength and workability only; adjustment techniques for volume change, thermal conductivity and sound transmission are recommended for future research.