Pretreatment alternatives for wastewater from oil tank farm and related oil product manufacturing

By: Call Number: AIT Thesis no.EV-81-16 Contributor(s): Material type: Continuing resourceSeries: Asian Institute of Technology. Thesis ; no. EV-81-16Publication details: Bangkok : Asian Institute of Technology, 1981Description: 121 : illSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1981 Summary: Shell CNS 'oil installation was utilized as a case study for its oily waste problem. Investigations were carried out on the existing treatment system believed to be ineffective. Sources and characteristics of waste~ water from oil tank farm and related oil product manufacturing were evalu- ated. Treatability studies of discharges with very high oil concentrations (mainly free oil and tempOrary emulsions) ranging from 70 to 2,240 mg/l were conducted using two types of 6il separators, namely, oil interceptor and compact plate separator (CPS). Performance of the oil interceptor~ a very simple form of gravity separator ·for oil-water mixtures,revealed a removal efficiency as high as 90% with effluent concentration of less than 15 mg/l oil and grease for a properly designed and maintained unit. Pilot-plant o~eration of the compact plate separator at the optimum flow rate of 2.5 m /h demonstrated an oil removal efficiency of more than 90% even without external heating. -However, better effluents were observed when it was coupled with an oil interceptor.serving as auxiliary unit. Both treatment systems are inexpensive from the point of view of a wealthy industry.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.EV-81-16 (Browse shelf(Opens below)) 3 Available 30050120655773
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.EV-81-16 (Browse shelf(Opens below)) Available 30050160084645
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no.EV-81-16 (Browse shelf(Opens below)) 1 Available 30050121075229

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development

Thesis (M.Eng.) - Asian Institute of Technology, 1981

Shell CNS 'oil installation was utilized as a case study for its oily waste problem. Investigations were carried out on the existing treatment system believed to be ineffective. Sources and characteristics of waste~ water from oil tank farm and related oil product manufacturing were evalu- ated. Treatability studies of discharges with very high oil concentrations (mainly free oil and tempOrary emulsions) ranging from 70 to 2,240 mg/l were conducted using two types of 6il separators, namely, oil interceptor and compact plate separator (CPS). Performance of the oil interceptor~ a very simple form of gravity separator ·for oil-water mixtures,revealed a removal efficiency as high as 90% with effluent concentration of less than 15 mg/l oil and grease for a properly designed and maintained unit. Pilot-plant o~eration of the compact plate separator at the optimum flow rate of 2.5 m /h demonstrated an oil removal efficiency of more than 90% even without external heating. -However, better effluents were observed when it was coupled with an oil interceptor.serving as auxiliary unit. Both treatment systems are inexpensive from the point of view of a wealthy industry.