Assessment of local ductility response reduction factors of 42-story and 30-story reinforced concrete dual system buildings

By: Call Number: AIT Thesis no.ST-21-06 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Thesis ; no. ST-21-06Publication details: Pathum Thani, Thailand : Asian Institute of Technology, 2021Description: 122 leaves : illSubject(s): Online resources: Dissertation note: Thesis (M. Eng.) - Asian Institute of Technology, 2021 Summary: Response ductility reduction factors (m-factors) were investigated on both 42- story and 30-story RC dual system buildings. This study covers the deformation- controlled actions of beams, shear walls, and coupling beams. Based on the data extracted from time history analysis at increasing hazard levels, local ductility reduction is showed to be higher than story ductility reduction and story ductility reduction is higher than global ductility reduction (mL > ms > me). Moreover, ductility demand presents a nonlinear increase while local ductility response reduction showed a linear increase with respect to the spectral geometric mean. Consequently, mL and /1L relationship for all members presents a nonlinear increase. Relationships between local and global ductility response reduction factors were also established based on the regression of different parameters (me, /11> Sa). In this case, if the local ductility demand is taken as the basis of design, the local ductility response reduction (md can be determined or vice versa. The proposed relationship is based on the idea that the ductility reduction factor should be applied locally since different nonlinearities are experienced by each member. It was evaluated using a 40- story case study building and the result showed a good prediction of the true nonlinear demands in comparison with the linear demands based on reducing the forces at the global level.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
67-Electronic Resource Asian Institute of Technology Library Archives AIT Thesis no.ST-21-06 (Browse shelf(Opens below)) Not for loan
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.ST-21-06 (Browse shelf(Opens below)) 1 Available 30020220004553

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Structural Engineering, School of Engineering and Technology

Thesis (M. Eng.) - Asian Institute of Technology, 2021

Response ductility reduction factors (m-factors) were investigated on both 42- story and 30-story RC dual system buildings. This study covers the deformation- controlled actions of beams, shear walls, and coupling beams. Based on the data extracted from time history analysis at increasing hazard levels, local ductility reduction is showed to be higher than story ductility reduction and story ductility reduction is higher than global ductility reduction (mL > ms > me). Moreover, ductility demand presents a nonlinear increase while local ductility response reduction showed a linear increase with respect to the spectral geometric mean. Consequently, mL and /1L relationship for all members presents a nonlinear increase. Relationships between local and global ductility response reduction factors were also established based on the regression of different parameters (me, /11> Sa). In this case, if the local ductility demand is taken as the basis of design, the local ductility response reduction (md can be determined or vice versa. The proposed relationship is based on the idea that the ductility reduction factor should be applied locally since different nonlinearities are experienced by each member. It was evaluated using a 40- story case study building and the result showed a good prediction of the true nonlinear demands in comparison with the linear demands based on reducing the forces at the global level.