The assessment of the distribution network and power supply of Sihanoukville
Call Number: AIT RSPR no. ET-96-1 Material type:
SeriesSeries: Asian Institute of Technology. Research studies project report ; no. ET-96-1Publication details: Bangkok : Asian Institute of Technology, 1996Description: 74 leavesSubject(s): Online resources: Dissertation note: Research Studies Project Report (M.Eng.) - Asian Institute of Technology, 1996 Summary: This research study has been written to survey load consumption for the consumers as: residential consumer, commercial consumer, industrial consumer, governmental agencies, and public consumer. Load demand reserve for load growth 10 % from 1996 to 2009. The design of distribution system consider about the supplying electricity to the customers by some characteristics, cross section of conductors, power loss, voltage drop. To compare those characteristics between 6.3 kV, 22 kV, and 44 kV which voltage level is better. The improving of power factor from 0.8 to 0.9 by selecting capacitor banks to reduce the reactive power. Furthermore the future expansion and operation and maintenance are studied. Also consider about the economic evaluation for selecting the best of three voltage levels by comparing some characteristics above. Finally the environment domain is focused by considering the visual impact, social impact and health impact.
| Cover image | Item type | Current library | Home library | Collection | Shelving location | Call number | Materials specified | Vol info | URL | Copy number | Status | Notes | Date due | Barcode | Item holds | Item hold queue priority | Course reserves | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT RSPR no. ET-96-1 (Browse shelf(Opens below)) | 1 | Available | 30050120614531 | |||||||||||||
20-AIT Publication
|
Asian Institute of Technology Library AIT Publications | AIT RSPR no. ET-96-1 (Browse shelf(Opens below)) | 2 | Available | 30050120614523 | |||||||||||||
40-Archives
|
Asian Institute of Technology Library Archives | AIT RSPR no. ET-96-1 (Browse shelf(Opens below)) | Available | 30050160015383 |
A research study in partial fulfillment of the requirements for the degree of Master of Engineering
Research Studies Project Report (M.Eng.) - Asian Institute of Technology, 1996
This research study has been written to survey load consumption for the consumers as: residential consumer, commercial consumer, industrial consumer, governmental agencies, and public consumer. Load demand reserve for load growth 10 % from 1996 to 2009. The design of distribution system consider about the supplying electricity to the customers by some characteristics, cross section of conductors, power loss, voltage drop. To compare those characteristics between 6.3 kV, 22 kV, and 44 kV which voltage level is better. The improving of power factor from 0.8 to 0.9 by selecting capacitor banks to reduce the reactive power. Furthermore the future expansion and operation and maintenance are studied. Also consider about the economic evaluation for selecting the best of three voltage levels by comparing some characteristics above. Finally the environment domain is focused by considering the visual impact, social impact and health impact.