Quasi-dynamic loading test on reinforced concrete columns

By: Call Number: AIT Thesis no.ST-82-15 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. ST-82-15Publication details: Bangkok : Asian Institute of Technology, 1982Description: vii, 44 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1982 Summary: This study deals with an experimental investigation of the restoring force characteristics of cantilever-type reinforced concrete columns. The main objectives of this investigation are to obtain the dynamic load-deflection curves (the hysteresis loops), the equivalent column stiffness and the equivalent viscous damping factor of the column. The equivalent column stiffness and the equivalent viscous damping factor obtained from the various dynamic tests are discussed. The recorded dynamic hysteresis loops could provide continuous data which in tern can be used for the identification of parameters of a cubic equation model. The test results show that the column stiffness reduces rapidly with an increment of the deflection, even in small amplitude. The damping capacity have a tendency to increase with increasing deflection.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.ST-82-15 (Browse shelf(Opens below)) 3 Available 30050120687438
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.ST-82-15 (Browse shelf(Opens below)) 1 Available 30050160013438

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering School of Engineering and Technology

Thesis (M.Eng.) - Asian Institute of Technology, 1982

This study deals with an experimental investigation of the restoring force characteristics of cantilever-type reinforced concrete columns. The main objectives of this investigation are to obtain the dynamic load-deflection curves (the hysteresis loops), the equivalent column stiffness and the equivalent viscous damping factor of the column. The equivalent column stiffness and the equivalent viscous damping factor obtained from the various dynamic tests are discussed. The recorded dynamic hysteresis loops could provide continuous data which in tern can be used for the identification of parameters of a cubic equation model. The test results show that the column stiffness reduces rapidly with an increment of the deflection, even in small amplitude. The damping capacity have a tendency to increase with increasing deflection.