    <title>Response to electricity time-of-use rates : case of selected industries in Taiwan</title>
  </titleInfo>
  <name type="personal">
    <namePart>Chou, Chi-yu</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Mohanty, B.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Shrestha, Ram M.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Surapong Chiraratananon</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>The Government of R.O.C</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1992</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>121 leaves : ill.</extent>
  </physicalDescription>
  <abstract>Owing to the rapid economic growth in the last few years  together with peoples' growing awareness of environmental  protection, Taipower is encountering a series of difficulties  of power shortages and severe protests against building new  generating facilities. Also, many industrial and commercial  customers together with some residential customers have  already experienced bitter power shortages.  Time-Of-Use (TOU) tariff rate structure was introduced  twelve years ago for implementing the goal of demand-side  management.  A number of technologies exist that can help both the  TOU customers to reduce electricity cost and the Taipower to  avoid setting up new power plants while supplying electricity.  Potential applications of a few of these technologies in two  selected industries in Taiwan have been covered in this study.  Results of the study show that technologies such as  vapor absorption chillers, vapor compression chillers using  waste streams of the plant can provide high internal rate of  return of over 60% and the investments can be recovered within  a year or two. The industries should implement these in order  to minimize the energy cost in production.  Other technologies such as cogeneration or heat pumps  using off-peak electricity have payback periods ranging from  3 to 7 years and the internal rate of return are of the order  10 to 30%. These may not be attractive to the industries  because their investment may be in direct competition with  those linked with plant's production I expansion capacity.  Suitable schemes should be provided by the sectional  authorities in order to encourage the implementation of load shi fting technologies that win benefit both Taipower as well  as individual industries. </abstract>
  <note>A thesis report submitted in partial fulfillment of the requirements for the degree of Master of Engineering</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology</note>
  <subject authority="lcsh">
    <topic>Electric utilities</topic>
    <topic>Taiwan</topic>
    <topic>Rates</topic>
    <topic>Time-of-use pricing</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ET-92-4</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B16246</identifier>