<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02525nas|a2200385 i 4500</leader>
  <controlfield tag="005">20260818212835.0</controlfield>
  <controlfield tag="008">121095s1986    th uu m rtt  00|  a1eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b1057394x</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2=" ">
    <subfield code="a">AIT RSPR no. IE-86-20</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Wichan Puangmaha</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">River water quality modeling under a stochastic environment</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bangkok :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">1986</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">53, C-16 p.</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Research studies project report ;</subfield>
    <subfield code="v">no. IE-86-20</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A research study report submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1986</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">A stochastic programming model for river water quality  management has been developed. The proposed model recognizes  explicitly the stochastic phenomena of streamflow and wastewater  flowrates. Furthermore, the uncertainties present in physical and  chemical parameters (i.e., reaeration constant, time of flow ) in  a water body due to the stochastic flows are taken into account  by the model.  A chance cons trained programming technique is employed in  this study because of its advantage in the replacement of  probabilistic constraints with their deterministic equivalents. A  simulation model is used together with an optimization model in  order to characterize uncertain elements and to predict water  quality at any point in a river basin.  </subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Water quality management</subfield>
    <subfield code="x">Mathematical models</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Fujiwara, Okitsugu, </subfield>
    <subfield code="e">Chairpeson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Saeed, Khalid, </subfield>
    <subfield code="e">Examiantion Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Hanaki, Keisuke, </subfield>
    <subfield code="e">Examiantion Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">The Government of France</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Research studies project report ;</subfield>
    <subfield code="v">no. IE-86-20</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B19560</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b1057394x</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">y</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240409</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">2</subfield>
    <subfield code="c">951012</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">y</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">22</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">40</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120724249</subfield>
    <subfield code="b">CREATED : 2012-10-10</subfield>
    <subfield code="c">RECORD # : i1270393x</subfield>
    <subfield code="d">LPATRON : 1024152</subfield>
    <subfield code="e">LCHKIN : 2013-01-10</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 1</subfield>
    <subfield code="j">TOT RENEW : 1</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050160109442</subfield>
    <subfield code="b">CREATED : 2016-08-04</subfield>
    <subfield code="c">RECORD # : i12932930</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">102388</subfield>
    <subfield code="d">102388</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. IE-86-20</subfield>
    <subfield code="p">30050120724249</subfield>
    <subfield code="r">2026-08-18 21:28:35</subfield>
    <subfield code="t">3</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">22</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. IE-86-20</subfield>
    <subfield code="p">30050160109442</subfield>
    <subfield code="r">2026-08-18 21:28:35</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">40</subfield>
  </datafield>
</record>
