<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Sensors and Smartphone Based Real-Time Heart Minitoring, Alarming and Reporting Systems</title>
  </titleInfo>
  <name type="personal">
    <namePart>Priyanka Kakria</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Nitin K. Tripathi</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Sarawut Ninsawat</namePart>
    <role>
      <roleTerm type="text">Examination committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Peeyush Soni</namePart>
    <role>
      <roleTerm type="text">Examination committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Peerapong Kitipawong</namePart>
    <role>
      <roleTerm type="text">Examination committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Asian Institute of Technology Fellowship</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Pathum Thani, Thailand</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>2016</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>1 online resource (106 p.) : ill. </extent>
  </physicalDescription>
  <abstract>The  World is experiencing a high rate of  cardiac diseases during last few decade s in which h eart  diseases have become one of the leading  causes of death . According to  World Health Organization  (WHO) , the  cardiovascular diseases are the world{u2019}s largest killers, claiming 17.1 million lives in a year. The hospital admission mainly  focused in the old er adults segment, range from a prevalence  of 1.5% to 8.4% in 50 {u2013} 65 years and 65 years or older groups, respectively. Admissions to hospital  with heart failure have significantly doubled in the last 20 year. Th ese critical issu es in connection  with  growing demand for better quality of life have raised the public concern regarding the need  for cardiovascular healthcare system s.  On the other hand, online telemedicine systems are being  considered useful and necessary  for providing efficient healthcare services .  The rapid growth in  wireless and communication technolog ies has remarkably enhanced the scope of health monitoring  systems .  Vital  sign  monitoring  systems  are  rapidly  becoming  the  core  of  today{u2019}s  healthcare  deliveries.  The  paradigm  has  shifted  from  tradi tional  and  manual  recording  to  computer  based  electronic  records  and  further  to  handheld  devices  as  versatile  and  innovative  healthcare  monitoring systems.  In the present study, a real - time heart monitoring system has been developed for collect ing real - time cardia c data from remote patients,  evaluation of m ultiple vital signs, long - term monitoring ,  and a wireless connection to the doctor at a super specialty hospital in an emergency . The main  aim of this research is to facilitate the  connection bet ween  remote  patient and doctor  which might  not be possible otherwise due to low doctor - to - patient ratio .  The developed monitoring system can  continuously acquire multiple vital signs and further relayed those to an intelligent data analysis  scheme to diagn ose  anomalies for  diagnosing potential chronic diseases.  Furthermore, this study  analyzed the acquisition of ECG (electrocardiogram) signal from the wearable sensor by detecting  noise  from  the  electrocardiogram  waveform.  Acquired  ECG  signals  are  then  compa red  with  available ECG data bases (MIT - BIH database).  Arduino UNO has been used for visualizing and  storing  the  signal  in  real - t ime.  It  stores  the  extracted signal  from the sensor and  then  sends  to  doctor{u2019}s interface to calculate R - R peak detection and QRS  detection. This ECG signal processing  helps  the  medical  experts  to  analyze  the  status  of the patient at the initial stage.  The  developed  system has a user friendly web interface for medical experts to observe immediate pulse signals  for  monitoring  patients remotely.  Once  abnormal  event  happened in  vital  signs ,  data  will immediately  transmit to remote medical ser ver through  the  internet (Wi - Fi  and 3G /4G ) .  An alert mechanism has been also developed for each vital parameter to give warning messages to  the patients in case his/ her heart rate is going critical. In Alert mechanism, threshold values for  each vital parameter  ha ve been designed after referrin g the medical research reports l ike European  Society  of  Hypertension,  World  Congress  of  Cardiovascular  Health  and  also  discussed  with  medical  experts  inside  Thammasat  Hospital  Thailand.  When  the  measured  data  exceeds  the  threshold range, the system sends an alarm message to the doctor{u2019}s  web server. The key contributions of the dissertation include: 1. The  protocol  of  developed  system  has  been  successfully  developed  and  implemented,  which  offered a high standard  of healthcare with a major reduction in medical cost.  More broadly, the system is conceptualized  to  provide  an  interphase  between  doctor  and  the  patients  for  two  way  communications by considering cost, ease of application, accuracy and data security. 2. Android  listening  port  has  been  created  to  receive  and  store  medical  information  of  th e  patient  which is then transmitted to the web interface using wireless communication.  The w eb interface    iv has been designed to be on the doctors{u2019} side so as to inform them of the medical status along with the location of the patient in real - time . 3. An  alarmin g  system  based  on  threshold  values  has  also  been  designed  which  sends an alert message to the doctor in case of  a nomalies such as arrhythmia, hypotension, hypertension, fever,  and hypothermia. It has been found that the time taken for sending alarm from patient to doctor is  30  secs  under  Wi - Fi  protocol  and  under  3G  it  is  approximately  56  secs  between  sending  and  receiving the alarm .  It  has  been found  that  the  alarm sending  time  for  both  of  thes e  wireless  protocols is under an acceptable range of medical standards (4 to 6 minutes as per American Heart Association ). 4. In order to evaluate and show the practical implementation, the developed system has been used  to monitor sixty five (65) cardiac pat ients located far away from the designed web application. The  data obtained through the developed system is found to be significantly acceptable when compared  with the hospital{u2019}s conventional machines.5. This study provides a framework of Real - time low cost ECG monitoring system which performs  the real - time ECG signal acquisition from patient{u2019}s body via wearable sensor. The acquired real - time data from the sensor is then transferred to windows based app lication which is installed on  d octor{u2019}s  computer.  Furthe rmore,  the  developed  ECG  system  provides  the  noise  detection  al gorithm  based  on  Wavelet  based  t ransformations  which  includes  the  R - R  detection,  QRS  and  HR (heart rate) calculation. The proposed algorithm also provides the noise detection in acquired  ECG si gnal from the wearable sensor.  The performance of the proposed system has been evaluated  against the MIT - BIH normal arrhythmia  database . ECG signals from the electrodes are amplified  with  a  gain  of  300  and  filtered  with  the  cut - off  frequencies  of  0.5Hz  in  the  high  pass  filter  and  100Hz  in  the  low  pass  filter .  The  ECG recordings  are digitized  at  360  samples  per  second  per  channel over a 10 mV range . It has been reported that the system is able to detect at an R - peak  with  a  success  rate  of  97.8%  and  it  is  als o  able  to  detect  abnormal  heartbeat  condition  with  a  success rate of 78.9%. The total delay in real - time ECG monitoring system is 94ms. On comparing  wit h the existing algorithms, Pan - T ompkins algorithm causes around 148ms. So, developed ECG  monitoring algo rithm given less time delay during signal analysis .  6. The p resent study demonstrates the applicability of remote care monitoring and it assures the 24/7  continuous screening to patients residing at distance from hospitals. The experimental validation  proces s has been done for remote patients residing 10 - 100 km away from the hospital server. From this  study , it can be stated that the proposed system is convenient, reliable, low cost, accurate,  real  time  and  ensures  data  security.  The  developed  system  would  in form  the  doctor  in  case  of  emergency  through  alarms; however,  delay  in  alarms  might  occur  due  to  weak  signals  of  3G  networks in some remote areas. Though the delayed alarming time is still within the golden period  of time (time  period  is  given by medical e xperts in World Heart Federation) yet improvement in  alarming lead time should be considered in future research.  As wireless technology is emerging  day by day, the u se of latest wireless technologies may overcome  these issues which ultimately  increase the applicability and usefulness of the proposed remote monitoring system. Furthermore, the false alarms can be generated due to the battery issues of sensors and smartphone.  The research  can  be  extended  to  overcome  these  battery  and  false  alarm  limitatio ns.  This  study  could  be  continued for the improvement of the ECG algorithm to detect further abnormalities in different  types of heart diseases such as Hypertension and Heart stroke.</abstract>
  <note>A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor of Engineering in Remote Sensing and Geographic Information Systems</note>
  <relatedItem type="series">
    <titleInfo>
      <title>Dissertation ; no. RS-16-04</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B00779</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B00779</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">210702</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818213743.0</recordChangeDate>
  </recordInfo>
</mods>