<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02924nas|a2200385 i 4500</leader>
  <controlfield tag="005">20260818214147.0</controlfield>
  <controlfield tag="008">261198s1987    th  uzm rtt  00|  a1eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b10717651</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT RSPR no. ET-87-8</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Wang, Yaw-juen</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="4">
    <subfield code="a">The sizing of stand-alone photovoltaic systems</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bangkok :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">1987</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">65 p.</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Research studies project report ;</subfield>
    <subfield code="v">no. ET-87-8</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A research study (9 credits) submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Research Studies Project Report (M. Eng..) - Asian Institute of Technology, 1987</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">A computer program in BASIC was developed to simulate the  performance of stand -alone photovoltaic systems . The simulation  was designed to ascertain that photovoltaic system reliability  indexes, i.e. cumulative loss of load hours (LOLH) over one year,  can be determined according to the meteorological conditions in  Thailand, consumer consumption patterns, array size and battery  size . The results of the simulation indicate that for a given  load profile , there exist several combinations of array size and battery capacity which meet a prescribed system reliability .  Economic analysis is introduced in order to allow for a  trade-off between array size and battery capacity to meet a  specified system reliability. The minimum cost f or meeting a  prescribed system reliability is found a t the point where the  marginal rate of substitution between array size and battery  capacity is equal to the ratio of the array price to the battery The optimum degree of system reliability is thus determined by considering the cost of the system against the cost of running the backup power source, i.e. a diesel set, a given number of hours.</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="0">
    <subfield code="a">Photovoltaic power generation</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Lasnier, France, </subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Exell, Robert H.B., </subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Bhattacharya, Sribas C.,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">THE RET-SER ENGINEERI NG AGENCY, ROC, </subfield>
    <subfield code="e">Scholarship Donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Research studies project report ;</subfield>
    <subfield code="v">no. ET-87-8</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B18993</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b10717651</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">y</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240402</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">2</subfield>
    <subfield code="c">951012</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">y</subfield>
    <subfield code="g">4</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">22</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">40</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120614812</subfield>
    <subfield code="b">CREATED : 2012-10-10</subfield>
    <subfield code="c">RECORD # : i1270121x</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050160016126</subfield>
    <subfield code="b">CREATED : 2016-03-31</subfield>
    <subfield code="c">RECORD # : i12916912</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">107466</subfield>
    <subfield code="d">107466</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. ET-87-8</subfield>
    <subfield code="p">30050120614812</subfield>
    <subfield code="r">2026-08-18 21:41:47</subfield>
    <subfield code="t">3</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">22</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. ET-87-8</subfield>
    <subfield code="p">30050160016126</subfield>
    <subfield code="r">2026-08-18 21:41:47</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">40</subfield>
  </datafield>
</record>
